Feature Definitions – Detangle(2)
13
•
When the Detangle feature is selected, the control will execute a reversing
tumble profile.
•
When the Detangle feature is not selected, the control will execute a Non-
reversing tumble profile.
•
When the Detangle Option is changed during the Run State, the control will stop
the drum, and start the new Tumble Profile.
•
There is a delay of six seconds before reversing the Drum Motor to allow for an
empty/nearly empty drum to stop to ensure the drum motor has stopped to
ensure motor reversal.
NOTE: No heat will be applied during the clockwise tumbling steps of the tumble
profile.
NOTE: The Mist Valve will not be energized during the clockwise tumbling steps of
the tumble profile.