Navigating Service Mode Tests
69
• Rotating the knob counter clockwise shall decrement the
test number in the display.
• Rotating the knob clockwise shall increment the test
number in the display.
• Once the test number is selected, pressing Start/Pause
shall begin the selected test.
•
Individual Service Mode tests are exited by turning the selector knob
to a different test number.
NOTE: If there is no model information programmed, all segments of
the 7-Segment Display and LEDs shall blink and must be set as
described in the (t1) section Setting Model Codes on an Uninitialized UI
Card prior to entering Field Service Mode.