Service Mode Tests
85
(t11) Water Valve Test:
* The control shall turn on the water valve relay and the drum motor when the
start button in pressed (“On” will be displayed). When the start button is
pressed again the relay will be turned off (“OFF” displayed).
* A beep shall be sounded every time the start button is pressed.
* Control will turn off the valve and the drum motor when the door is opened.
* The control will turn off the valve and the drum motor when the test mode is
changed.
* The control shall turn off the valve and the drum motor if the Field Service
mode is exited.
* When the valve and drum motor are turned off by the previous three
conditions when the executing the test, the user must press start to restart the
test to turn on the drum motor and steam relay.