– 61 –
Test
Mode
Press Displays Exit
t10 Start/
Pause
Tumble test . Displays tt . Wash basket spins in one direction for 5
seconds, pauses, then spins in the opposite direction for 5 seconds.
Repeats until exit initiated. (Note: Beginning direction is random.)
Press Power.
Pump runs.
Returns to
t10
t11 Start/
Pause
Spin speed-low spin/high spin test . Display shows rpm. Pump runs,
displays 0, then wash basket ramps to 400 rpm. Press Start/Pause a
second time to ramp to 1100 rpm. (Display B00). Press Start/Pause again,
on models ramp to 1300 rpm (display D00). Then motor is unpowered,
display 0, pump runs, and returns to t11.
Press Power.
Pump runs.
Returns to
t11
t12 Start/
Pause
Dispenser motor/mechanism test . Press Start/Pause to advance.
'LVSOD\V3GWDQG¿OOVYLDSUHZDVKFRPSDUWPHQW'LVSOD\VGGWDQG¿OOV
YLDZDVKFRPSDUWPHQW'LVSOD\VEGWDQG¿OOVYLDEOHDFKFRPSDUWPHQW
'LVSOD\V)GWDQG¿OOVYLDIDEULFVRIWHQHUFRPSDUWPHQW1RWH,IPDLQ
level reached during test, dispenser operation stops, pump runs, and
returns to t12.)
Press Power.
Pump runs.
Returns to
t12
t13 Start/
Pause
EOL test sequence. Not used for service. Press Power. Returns to
t13