(See rating decal, located
Rated Capacity* on the Softener)
Amount of high capacity resin (lbs/cu. ft) 31.2/.6
Resin tank nominal size (in., dia. x height) 8 x 40
Service flow rate (gpm) 7.5
Water supply maximum hardness (gpg) 50
Water supply maximum clear water iron (ppm)** 3
Water pressure limits (min.-max. psi) 20-125
Pressure drop at rated service flow (psig) 15
Water temperature maximum (°F) 120
Water supply minimum flow rate (gpm) 3
Regeneration cycle flow rates (gpm)
Fill (flow to brine tank) .3
Brining .19
Brine Rinse .12
Backwash 1.8
Fast Rinse 1.8
}
(flow to drain)
11
Specifications/Dimensions
This system conforms to WQA S-100 for the specific capacity claims as verified and substantiated by test data.
* Testing was performed using pellet grade sodium chloride as the regenerant salt.
** Extent of iron removal may vary with conditions. Use of Diamond Crystal® Red•Out® or Super Iron Out® will
improve iron removal. Refer to
Cleaning Iron Out of the Water Softening System
section.
11
1
⁄2″
3
3
⁄8″
OUT
INLET
INLET-OUTLET
48
3
/4″
41
1
⁄4″
18
1
⁄4″
40
1
⁄2″