DIMENSIONS AND INSTALLATION INFORMATION
Listed by
Underwriters
Laboratories
PGP9830DJ/TJ
GE Profile
Series 30" Downdraft Gas Cooktop
For answers to your Monogram, GE Café
Series, GE Profile
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
Specification Revised 4/16
*NOTE: A 5" minimum spacing to adjacent side wall is required
Dimension and installation information are shown in inches.
WALL INSTALLATION : Wall installations
require 25" countertop depth. When cabinet
is flush against the wall, the fan housing can
be rotated to the horizontal position for direct
venting through rear wall. Make a countertop
cutout in the range cabinet according to unit
dimensions and installation type. Duct hole is
positioned in back of cabinet for through-the-
wall ducting.
PENINSULA OR ISLAND INSTALLATION:
For peninsula/islands a minimum 26"countertop
depth is suggested. Blower should be in vertical
position. Island or peninsula cabinets may
require adjustment in cutout depth and/or
location within the width dimensions. Duct hole
is positioned in bottom of cabinet for island or
peninsula installation.
SLAB INSTALLATION: For peninsula or
island installation and rear wall ducting, 6" PVC
duct or locally approved piping should be used
if installing under a poured concrete slab.
INSTALL ATION INFORMATION: Before
installing, consult installation instructions,
packed with product, for current dimensional
data.
NOTE: These cooktops are approved for indoor
use only.
20
9
4
10-1/2
16
C
L
21
7
8ʺ
(21
15
16ʺ SS)
20
1
2ʺ
22ʺ
29
3
4ʺ
2
3
16ʺ
(2
1
4ʺ
SS)
28
3
4ʺ
25
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
*U.L. Requirement.
Note: A 5" minimum spacing to adjacent side wall is required
(29
13
16ʺ SS)
21
7
8ʺ
(21
15
16ʺ SS)
20
1
2ʺ
22ʺ
29
3
4ʺ
2
3
16ʺ
(2
1
4ʺ SS)
28
3
4ʺ
25
1-7/8"
MIN. Required*
20-5/8
Cut-out Dimensions (in inches)
28-7/8
*U.L. Requirement.
Note: A 5" minimum spacing to adjacent side wall is required
(29
13
16ʺ SS)
Question and Answer IconNeed help?

Do you have a question about the GE Profile PGP9830DJ and is the answer not in the manual?

GE Profile PGP9830DJ Specifications

General IconGeneral
BrandGE
ModelProfile PGP9830DJ
CategoryCooktop
LanguageEnglish

Summary

Dimensions and Installation Information

Wall Installation

Wall installations require 25" countertop depth. Fan housing can be rotated for rear venting through the wall.

Peninsula or Island Installation

Minimum 26" countertop depth suggested. Blower should be vertical. Cabinets may require adjustment.

Slab Installation

For peninsula/island/rear wall ducting, 6" PVC duct or approved piping for concrete slabs.

Installation Information

Consult installation instructions packed with product for current dimensional data before installing.

Ductwork Installation

Installing the Ductwork

Use 6" round or 3-1/4" x 10" duct. Vent to outside only. Max 100 ft equivalent length.

Features and Benefits

Downdraft Exhaust System

Powerful exhaust system effectively pulls smoke and steam out of the kitchen.

Gas on Glass Cooktop

Sleek and easy to clean surface.

Sealed Cooktop Burners

Keep spillover contained for quick and easy cleaning.

All-Purpose Burner

11,500 BTU burner delivers a wide range of heat output for most cooking needs.

Dishwasher-Safe Components

Grates and knobs are safe to clean in the dishwasher.

Model Information

Lists available models: PGP9830TJWW (True white), PGP9830DJBB (Black).

Guaranteed Fit Program

Guaranteed Fit

GE cooktops are guaranteed for an exact fit to make replacement easy.

Related product manuals