Safety
Target group
This tool may only be used by skilled persons in accordance with EN IEC 82079-1:2012.
Intended use
The Geberit pressing tool ACO 202 is only allowed to be used for pressing pipes and
pressfittings of the Geberit Mepla and Geberit Mapress pressing systems.
Only Geberit pressing attachments (pressing jaws, adapter jaws, pressing collars) with the
compatibility mark may be used with the ACO 202 pressing tool. The relevant overviews
regarding compatibility and the maximum pressing areas can be found in the country-specific
product range catalogues.
The Geberit pressing tool is not suitable for continuous operation. After 30 minutes of
continuous operation, a break of at least 15 minutes must be taken to allow the pressing tool
to cool.
Any other use or a use extending beyond the intended application is deemed to be improper.
Geberit will not accept any liability for any resulting damage.
Basic safety notes
WARNING: Risk of injury caused by flying fragments if used incorrectly or if worn or
damaged pressing attachments are used
Only use the pressing attachments (pressing jaws, pressing collars, adapter jaws) if they
are in perfect working order
Examine the pressing attachments regularly before and after each use for defects,
particularly for incipient cracks in the pressing contour and the retaining bracket, and also
for other damage. If there are cracks in the material, take the entire pressing attachment
out of service immediately and do not use it again
Do not use a pressing attachment again after it has been used incorrectly or in a way that
does not comply with its intended use. Instead, hand it over to an authorised repair shop
for testing
Adhere strictly to maintenance regulations and maintenance intervals for the pressing tool
and pressing attachments
Wear suitable protective equipment (protective goggles etc.)
Only have repair work carried out by Geberit or an authorised repair shop
Follow the country-specific safety regulations
Read through and note all safety notes and instructions relating to the pressing tool and
pressing attachments before commissioning. Failure to observe the safety notes and
instructions can lead to electric shock, fire and/or serious injuries. Store all safety notes
and instructions for the future