Error Cause Action
Unable to activate the
pressing tool out of idle
state and no LEDs are lit.
Rechargeable battery
is defective.
Replace the rechargeable battery
with a Geberit lithium-ion battery of
type Milwaukee18V.
Have the defective rechargeable
battery tested by an authorised repair
shop.
The rechargeable
battery has not been
inserted properly.
Insert rechargeable battery.
Pressing tool is
defective.
Have the pressing tool inspected by
an authorised repair shop.
Green LED flashes.
Rechargeable battery
not charged up suffi-
ciently.
Charge the rechargeable battery or
replace it with a Geberit lithium-ion
battery of type Milwaukee18V.
Retaining pin has not
been inserted
correctly.
Insert the retaining pin.
Retaining pin has
come loose.
Insert the retaining pin.
Check the pressing operation and
repeat if necessary.
Red LED flashes.
Pressing tool is
outside of the
operating
temperature.
Bring the pressing tool into a warmer
environment or leave it to cool down.
Bring the pressing tool to the required
operating temperature by performing
multiple blank pressing operations
(pressing operations without a fitting).
Incorrect or defective
rechargeable battery
inserted.
Replace the rechargeable battery
with a Geberit lithium-ion battery of
type Milwaukee18V.
Red LED lights up. Tool failure.
Press the start button. If pressing the
start button is not successful, the
pressing tool is defective. Have the
pressing tool inspected by an
authorised repair shop.
Check the pressing operation and
repeat if necessary.