Cleaning and lubricating the
Geberit pressing tool
WARNING
Risk of injury from switching on
inadvertently
Remove the rechargeable
battery before starting any
maintenance work on the
pressing tool.
ATTENTION
Damage to the device from moisture
Never clean the pressing tool with
water or other liquids.
1 Push in both release buttons on the
rechargeable battery and pull it out.
2 Clean the roller drive, roller drive
guide and retaining pin of the
pressing tool.
3 Use a brush to remove dirt.
CAUTION
Harmful substances
Observe the safety notes of
the lubricant used.
4 Lubricate the roller drive, roller drive
guide and retaining pin with
BRUNOX® Turbo-Spray®.
5 Wipe away excess lubricant using an