To cancel the welding procedure, press the start button.
<Welding procedure> LED display
goes out. Remove
the coupling connection plugs. <Malfunction> LED display
flashes. Press the start button and hold for three
seconds. <Malfunction> LED display
goes out.

Repeat the welding procedure with the cooled Geberit
electrofusion coupling or the cooled Geberit electrofusion
tape for anchor point.
4 Welding is completed after approx.80 seconds (in the case
of electrofusion couplings with integrated thermal fuse,
approx.7minutes).
<Welding procedure> LED display
goes out and
the <Welding complete> LED display
lights up
(see figureD, i , page394).
Result
Welding has been performed correctly.
46
9962820747 © 01-2023
966.473.00.0(03)