EasyManuals Logo

Gecko in.xe Quick Start Card

Gecko in.xe
2 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
P1: Pump 1
CP: Circulation Pump
Config.
#
P1 P2
BL CP config. Ozone configuration Filter Type
Heater
Pump
1 2sp 1sp X Always on --- Clean, P1L P1
2 2sp 1sp X Always on --- Purge CP
3 2sp 1sp X --- On during Filter cycle, with P1 Clean, P1L P1
4 2sp 1sp - Duration ltration On during Filter cycle, with CP Clean, CP P1
5 2sp 1sp - Always on Always on with CP Clean, P1L CP
6 2sp 1sp - Duration ltration On during Filter cycle, with CP Clean, CP CP
7 2sp 1sp - --- On during Filter cycle, with P1 Clean, P1L P1
8 2sp - X --- On during Filter cycle, with P1 Clean, P1L P1
9 2sp - - --- On during Filter cycle, with P1 Clean, P1L P1
10 1sp 1sp
X --- On during Filter cycle, with P1 Clean, P1L P1
11 1sp 1sp
- Duration ltration On during Filter cycle, with CP Clean, CP P1
12 1sp 1sp
- Always on Always on with CP Purge CP
13* 1sp
- - Always on Always on with CP Purge CP
Press and hold the
Pump
1 key for 30
seconds.


Use the Up/Down key
to choose the new de-
sired low level confi gu-
ration number and
press the Program or
light key to confi rm the
selected con guration
(consult the confi gura-
tion selection chart
section in this manual).
If the Program or light
key is not pressed with-
in 25 seconds, the unit
will exit this menu with-
out changing any settings.
If at power-up of the
system your keypad
display shows the
following message:
"L _ _ ", it means that
all low level con gura-
tions have been down-
loaded, but no confi -
guration number has
been chosen.
The keypad display
will show L xx where
"xx" represents the
previous confi guration
number registered in
the system.
Programming the in.xe™ using the keypad
4- Select proper Low Level
Note: This confi guration chart is valid for the sofware #85 revision 1 to 3.
This information is displayed on top side keypad at spa pack power-up.
Software number is displayed rst (ex: ), followed by revision (ex: ).
Con guration selection chart
* Confi guration #13 for software 85 Rev-03
Note: If the keypad in use does not have the
Program key, use the Light key instead.
9919-101154
© 2010 Groupe Gecko Alliance Inc.
TM trade-marks of/marques de commerce
de Groupe Gecko Alliance Inc.

Other manuals for Gecko in.xe

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gecko in.xe and is the answer not in the manual?

Gecko in.xe Specifications

General IconGeneral
Blower Output1
Ozone Output1
Light Output1
DimensionsVaries by model
WeightVaries by model
WarrantyVaries by manufacturer
Power Supply240V
Keypad Compatibilityin.k200, in.k300, in.k35, in.k4, in.k450, in.k500, in.k600, in.800 Auxiliary Keypads: in.k100

Related product manuals