For 240 V (4 wires)
Connect wiring of the electrical
service box GFCI. Neutral wire is
mandatory.
For 120 V (*3 wires)
* If connected to a 3 wire system,
any 240 V components will
not work.
2- Connect the main power
1- Connect all outputs & keypads
L2
N
L1
G
in.ye-5
™
whatever the spa, this is your control system
North American version
This Quick Start Card is intended for users of the North American
version of the in.ye.
Heater
C1 - Main keypad connector
Light outputs
(P34 always on, P35 relay controlled)
CO - Communication links (2 ports)
in.touch, in.stick, Aux keypad in.k112
or in.k120 or Swim Spa com. cable
Main power
entry connection
Heater
connections
Bonding lugs
A0 Direct
H L GC
A4
A3
A2
A1
AMP ports (A0 to A4) for pumps
& accessories. Function varies per
configuration (see step 3).
WARNING
All connections must be made by a qualified electrician in accordance with the national electrical code and any state, provincial or local electrical
code in effect at the time of the installation. This product must always be connected to circuit protected by a Ground Fault Circuit Interrupter (GFCI).
PUMP 1
A1
A2
A3
A4
2.a- Electrical wiring
Heater voltage
Review BROWN common wire
connection to tab:
P9 - 240 V (default)
P10 - 120 V
Pumps & accessories voltage
Review each WHITE common
wire connection to tab:
N - 120 V (default)
L2 - 240 V pump/acc.
P9
2.b- Heater & pump/accessories voltage
P10
N
L1
G
Quick Start Card