Information between ( ) indicates which connector/tab to use. See drawing from Step 1 for connector position.
Configuration selection chart
Standard
config. #
Pump 1 Pump 2
Circ. Pump (CP)
configuration
Ozone (O3)
configuration
Filter cycle daily Heater
1
2SP
(K7-P, K6-P)
10A-3A
_ _ _
2 * 1 hour
with P1 Pump 1
2
1SP
(K7-P)
4A
_ _
X
(K6-P)
2 * 1 hour
with P1 Pump 1
3
1SP
(K7-P)
4A
1SP
(K6-P)
8A
_ _
2 * 1 hour
with P1 Pump 1
4
1SP
(K7-P)
10A
_
X
(K6-P)
2A
_
2 * 6 hour
with CP CP
5
2SP
(K7-P, K6-P)
10A-3A
_
Always on
(P-25)*
2A
_ 2 * day purge CP
Software #316, rev. 001
* Circulation pump is not controled via a relay and will run 24/7. Circulation pumps must provide at least 75 L/min (18 GPM) without creating kinetic heating of the water
(Gecko recommends using the Aqua-Flo Circ-Master - 1/15 HP).
For complete TechBook or more information, see our website: www.geckoalliance.com
9919-101444-B Rev. 06-2016
www.geckoalliance.com
© Groupe Gecko Alliance Inc., 2016
All trademarks or registered trademarks are the property of their respective owners.
Glossary
X Installed
1SP High speed only
2SP High and low speed
10A, 10A-3A Output current: 1 speed or High-Low speed