EasyManuals Logo

gefran 1300-RD00-00-0-x Quick Start Guide

gefran 1300-RD00-00-0-x
7 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
GEFRAN SpA
Via Sebina, 74 - 25050 PROVAGLIO D’ISEO (BS) ITALY
Note
Change all menu parameters by
using the front panel buttons
GETTING STARTED
• Unpack Contents
• Verify model numberand application
• Power Controller
• Program for yourapplication
Program Your Gefran Controller
2
*Parametermaybeleftatdefaultvalueforinputtypes0...37
Input Sensor
Sensor Type Sensor Type
0 TCJ°C 30 PT100°C
1 TCJ°F 31 PT100°F
2 TCK°C 32 JPT100°C
3 TCK°F 33 JPT100°F
4 TCR°C 34 PTC°C
5 TCR°F 35 PTC°F
6 TCS°C 36 NTC°C
7 TCS°F 37 NTC°F
8 TCT°C 44 4...20mA
9 TCT°F 46 0...10V
Connect Your Controller
3
What’s Included
• 96x96 DIN 1300-RRR0-00-0-x
Gefran Controller x2
• Mounting Bracket
• Panel Sealing Gasket
• Screw Terminal Cover x2
• Multi-Language Manual
1
• Pressandhold
F
untilPASappears—ENTER99
• Press
F
once,Proappears—ENTER128
• Press
F
once,PASappears—ENTER99
• Pressandhold
F
untilHrdappears
• Press
F
twice,Ctrappears—ENTER14
• Press
F
twice,
butappears—ENTER1
• Pressandhold
F
until
CFGappears
• Pressandhold
F
until
C.Meappears
—ENTER 0 coolingwithAir
—ENTER 1 coolingwithOil
—ENTER 0 coolingwithWater
• Pressandhold
F
until1 nPappears
• Press
F
twice,tYPappears—ENTERtheInputSensornumberfromthelist
• Press
F
repeatedlyuntilLo.S*appears—ENTERtheminimumInputScalelimit
• Press
F
once,H i.S*appears—ENTERthemaximumInputScalelimit
• Press
F
repeatedlyuntilLo.L*appears—ENTERtheminimumAlarmScalelimit
• Press
F
once,H i.L*appears—ENTERthemaximumAlarmScalelimit
• Pressandhold
F
until
Outappears
• Press
F
threetimes,rl.1appears—ENTER1
• Press
F
twice,rl.3appears—ENTER 2
• Pressandhold
F
untilyoureturntothemainprocessdisplay.ThisisthedisplayafterPAS
andwillbeindicatedbytheProcessVariableifaninputsensorisconnected,orLo,H i,Sbr,
Errifnoinputisconnected.
• Usethe
and
buttonstoadjustthecontrolsetpoint(SV)fromthemaindisplay.
• Press
F
oncefromthemaindisplay,AL.1appearstoadjusttheAlarm1setpoint.
• Press the
buttontoswitchbetween automatic andmanualcontrol modes fromthe
maindisplay.LED1(
L1
)willlightwhileinmanualmode.
POWER
This Quick Start Guide provides basic information on
setting up the Gefran 1300 controller for the application
referenced above. Additional software and hardware
configuration information can be found in the User’s Manual
included with this controller or online at www.gefran.com
If needed, automatic tuning (Self-Tune) can be enabled
with the following steps
• Pressandhold
F
untilCFGappears
• Press
F
once,S.Tuappears—ENTER2
• Press
F
once
• Cyclepowertothecontroller
• LED3(
L3
)willflashduringthetuningprocess
Withthemachineatambienttemperatureand
thecontrolsetpoint(SV)set...
Self-TunewillautomaticallysavenewPID
valuesoncecomplete
Additional wiring
configurations are
available in the User’s
Manual and General
Setup Guide
Quick Start Guide
1300-RRR0-00-0-x Programmable PID Controller
12
13
1
+
2
-
5
7
8
11
10
6
ALARM
COOLING
HEATER
Heat - Cool - Alarm
THERMOCOUPLE
2 / 7

Other manuals for gefran 1300-RD00-00-0-x

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran 1300-RD00-00-0-x and is the answer not in the manual?

gefran 1300-RD00-00-0-x Specifications

General IconGeneral
Brandgefran
Model1300-RD00-00-0-x
CategoryController
LanguageEnglish

Related product manuals