This Quick Start Guide provides basic information on
setting up the Gefran 1300 controller for the application
referenced above. Additional software and hardware
configuration information can be found in the User’s Manual
included with this controller or online at www.gefran.com
If needed, automatic tuning (Self-Tune) can be enabled
with the following steps
• Pressandhold
F
untilCFGappears
• Press
F
once,S.Tuappears—ENTER2
• Press
F
once
• Cyclepowertothecontroller
• LED3(
L3
)willflashduringthetuningprocess
Withthemachineatambienttemperatureand
thecontrolsetpoint(SV)set...
Self-TunewillautomaticallysavenewPID
valuesoncecomplete
Note
Change all menu parameters by
using the front panel buttons
GETTING STARTED
• Unpack Contents
• Verify model numberand application
• Power Controller
• Program for yourapplication
Program Your Gefran Controller
2
*Parametermaybeleftatdefaultvalueforinputtypes0...37
Input Sensor
Sensor Type Sensor Type
0 TCJ°C 30 PT100°C
1 TCJ°F 31 PT100°F
2 TCK°C 32 JPT100°C
3 TCK°F 33 JPT100°F
4 TCR°C 34 PTC°C
5 TCR°F 35 PTC°F
6 TCS°C 36 NTC°C
7 TCS°F 37 NTC°F
8 TCT°C 44 4...20mA
9 TCT°F 46 0...10V
Connect Your Controller
3
What’s Included
• 96x96 DIN 1300-RD00-00-0-x
Gefran Controller x2
• Mounting Bracket
• Panel Sealing Gasket
• Screw Terminal Cover x2
• Multi-Language Manual
1
• Pressandhold
F
untilPASappears—ENTER99
• Press
F
once,Proappears—ENTER128
• Press
F
once,PASappears—ENTER99
• Pressandhold
F
untilHrdappears
• Press
F
repeatedlyuntilbutappears—ENTER1
• Pressandhold
F
until1 nPappears
• Press
F
twice,tYPappears—ENTERtheInputSensornumber
fromthelist
• Press
F
repeatedlyuntilLo.S*appears—ENTERtheminimumInputScalelimit
• Press
F
once,H i.S*appears—ENTERthemaximumInputScalelimit
• Press
F
repeatedlyuntilLo.L*appears—ENTERtheminimumAlarmScalelimit
• Press
F
once,H i.L*appears—ENTERthemaximumAlarmScalelimit
• Pressandhold
F
untilyoureturntothemainprocessdisplay.ThisisthedisplayafterPAS
andwillbeindicatedbytheProcessVariableifaninputsensorisconnected,orLo,H i,Sbr,
Errifnoinputisconnected.
• Usethe
and
buttonstoadjustthecontrolsetpoint(SV)fromthemaindisplay.
• Press
F
oncefromthemaindisplay,AL.1appearstoadjusttheAlarm1setpoint.
• Press the
buttontoswitchbetween automatic andmanualcontrol modes fromthe
maindisplay.LED1(
L1
)willlightwhileinmanualmode.
POWER
Additional wiring
configurations
are available
in the User’s
Manual and
General Setup
Guide
Quick Start Guide
1300-RD00-00-0-x Programmable PID Controller
2
-
1
+
7
8
11
10
6
-
5
+
ALARM
Heat & Alarm
HEATER
POWER CONTROL
THERMOCOUPLE