31
80290C_MHW_2400_0908_ENG
PP RR OO
Protection Code
This menu lets you enable/disable the display and/or change of certain parameters.
(To access this menu, see the section “Using the controller menus”)
by adding the following numbers to the value shown in the table,
you can enable a series of supplemental functions:
+4: disable menus InP.1, InP.2, InP.3, InP.4, ALL, 0vt
+8: disable menus Ser
+16: disable software “on – off” from keyboard
+32: disable save tare
KKRRDD
Hardware Configuration
This menu lets you configure the hardware parameters.
(To access this menu, see the section “Using the controller menus”).
Process type and line frequency,
enable MD8 module
Process Line
type frequency
Fast to check
pressure, flow rate.
Slow to check
temperature
0 Fast 50Hz
2 Slow 50Hz
4 Fast 60Hz
6 Slow 60Hz
A
+8: digital inputs DI1, DI2, type NPN.
digital inputs NPN is on with open contact.
If you want reverse logic, set +64 in parameter diG.x
+16: enable MD8 expansion control
+ 32: disable menu rEL
xrd
Display Change
0 In.1, In.2, In.3,, In.4 AL.1, AL.2, AL.3
Fin.A, Fin.B, AL.4, ... AL.10
AL.1, AL.2, AL.3, ... AL.10
1 In.1, In.2, In.3,, In.4
Fin.A, Fin.B,
AL.1, AL.2, AL.3, ... AL.10
3 Fin.A, Fin.B,