CONTROLS
62
Accessories
Auxiliary Hydraulic Lines
WARNING
Oil may spray out if caps or filters are
removed or pipes disconnected before
releasing the pressure in the hydraulic
system.
When removing plugs or
disconnecting hoses, release the
internal pressure before removing.
Hydraulic uid, tubes, fittings and quick
couplers can get hot when running
machine and attachments.
Be careful when connecting and
disconnecting quick couplers.
These lines deliver the hydraulic oil necessary
for operating other attachments.
Auxiliary hydraulic flow rate and rated
pressure:
Flow Rate ...............
CTL55: 57 L/min (15.1 US gpm)
CTL65: 70 L/min (18.4 US gpm)
CTL75: 75 L/min (19.8 US gpm)
CTL85: 89 L/min (23.4 US gpm)
Rated Pressure ........ 20.6 MPa (2987 psi)
Quick-Couplers
Connecting: Remove dirt or debris from
the surface of both the male and female
couplers, and from the outside diameter of
the male coupler. Visually check the couplers
for corrosion, cracks, damage or excessive
wear. If any of these conditions exist, the
coupler(s) must be replaced.
Install the male coupler into the female
coupler. Full connection is made when the
ball-release sleeve slides forward on the
female coupler.
Disconnecting: Hold the male coupler.
Retract the sleeve on the female coupler
until the couplers disconnect.
Releasing Residual Pressure
Connecting: Push the quick-couplers tightly
together and hold for ve seconds; the
pressure is automatically released as the
couplers are installed.
Disconnecting: Push the quick-couplers
tightly together and hold for five seconds;
then retract the sleeve until the couplers
disconnect.
Connecting the Hydraulic Circuits
To connect attachment hydraulic lines, use
the following procedures:
1. Connect the attachment hydraulic lines to
ports (a) and (b).
When fitted with a hydraulic breaker:
a. Connect the return circuit to port (b)
and the supply circuit to port (a).
b. Turn on theow selector switch.
Refer to page 56 “Flow Selector
Switch.
Some attachments may have a case
drain, which needs to be the connected
to the small port (T).
2. When connecting is complete, purge air
from the hydraulic lines.
a. Start and run the engine at low idle with
no load for 10 minutes.
b. With the engine running at low idle,
operate the auxiliary hydraulics switch
repeatedly (approx. 10 times) to purge
air from the hydraulic lines.
c. Stop the engine and wait for more than
5 minutes until bubbles escape from
the hydraulic oil in the tank.