EasyManua.ls Logo

Gehl RS5-19 - Page 59

Gehl RS5-19
82 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PRINTED IN U.S.A. 57 50960066/AP0813
5. Use a trouble light inside the new outer element to
inspect for bad spots, pinholes and ruptures.
IMPORTANT: NEVER use an element that is
damaged. Severe engine wear and eventual fail-
ure can result if dirt gets through a hole in the ele-
ment. Cleaning the outer element is not recom-
mended.
NOTE: Replace the inner element only if it is vis-
ibly dirty or if the outer element has been replaced
three times.
Before removing the inner element from the housing,
clean out any dirt build up in the housing. Leave the
inner element installed during this step to prevent
debris from entering the engine intake manifold.
Remove the inner element.
6. Check the inside of the housing for any damage
that may interfere with the elements.
7. Be sure that the element sealing surfaces are clean.
8. Insert the element(s), making sure that they are
seated properly.
9. Secure the cover to the housing with the three
clamps.
10. Check the hose connections and make sure they
are all clamped and tightened properly.
11. Re-position the air cleaner in its mounting position
and re-install the wing nut.
CHANGING AXLE DIFFERENTIAL AND
PLANETARY OIL
Differentials
1. Remove the check/fill plug. Remove the drain plug
and drain out the old oil. Replace the drain plug
(see illustration).
IMPORTANT: DO NOT discharge oil onto ground.
Catch and dispose of per local waste disposal
regulations.
The air filter restriction indicator on the multi-function
display is lit whenever the air cleaner is restricted.
The outer element should be replaced anytime the
restriction indicator stays lit. The inner element should
be replaced every third time the outer element is
replaced, unless the outer element is damaged or the
inner element is visibly dirty. Along with a daily check
of the restriction indicator, check that the air cleaner
intake hose and clamps, and the mounting bracket
hardware are properly secure. Replace the filter fol-
lowing the procedure on this page:
1. In order to gain access to the latches and clearance
to remove the filter elements, remove the wing nut
retaining the air cleaner in its mounting position.
2. Unlatch the three latches on the air cleaner and
remove the cover. Clean out any dirt in the cover
assembly.
3. Carefully pull the outer element out of the housing.
Never remove the inner element unless it is to be
replaced.
4. Clean out any dirt in the housing. Leave the inner
element installed during this step to prevent debris
from entering the engine intake manifold.
Drain Plug
Check / Fill Plug
Air Cleaner Assembly
Secondary
Element
Primary
Element
Mounting
Band
Element
Cover
Dust
Ejector
Air Cleaner Latch
Wing Nut

Related product manuals