Document No. GUK0018/2007 issue 02 8 of 53
2.2 Imperial (Standard Gauge)
Measurements
Gauge: - - 0.75” to +2.0” mm datum set at 58.5”
Measurement accuracy:- +/- 0.04”
Cross Level (Cant):- +/- 8.0”
Accuracy:- +/- 0.04” over 0 – 8.0”
Track Twist: - +/- 4.0”
Measurement accuracy:- +/- 0.06”
Twist 1 base length :- adjustable in 0.125yd steps
Twist 2 base length :- adjustable in 0.125yd steps
Exceedance settings Gauge – 57.2” to 60.5” adjustable in 0.1” steps
Cross level default 0 - adjustable in 0.1” steps
Twist default 0 - adjustable in 0.1” steps
Distance: - Recorded every 0.125yds
Accuracy < 0.2”/yd
Adjustable in steps of 1yd when updating location
Measuring resolution 0.01”
Manual Event:- 3 Button text input
Text comment box
Batteries:- Integral rechargeable NiMH
Autonomy:- 20 hours (PDA see manufacturers )
Charging:- Via external 230vac input charging unit (others by request)
Charging Time:- 24 hours for complete charge
Operating Temperature:- 23°F to +104°F
Weight :- ≤22 lbs.excluding PDA
Size:- Folded for carrying, 43.5” long x 9.85” high x 19.7”” wide
Transit Case 47.8” long x 12.6” high x 22.1” wide
Total shipping weight in Transit Case 64lbs