EasyManua.ls Logo

GEISMAR Amber - Metric (Narrow Gauge); Imperial (Narrow Gauge)

GEISMAR Amber
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document No. GUK0018/2007 issue 02 8 of 53
2.2 Imperial (Standard Gauge)
Measurements
Gauge: - - 0.75 to +2.0 mm datum set at 58.5
Measurement accuracy:- +/- 0.04
Cross Level (Cant):- +/- 8.0
Accuracy:- +/- 0.04 over 0 8.0
Track Twist: - +/- 4.0
Measurement accuracy:- +/- 0.06
Twist 1 base length :- adjustable in 0.125yd steps
Twist 2 base length :- adjustable in 0.125yd steps
Exceedance settings Gauge 57.2 to 60.5 adjustable in 0.1 steps
Cross level default 0 - adjustable in 0.1 steps
Twist default 0 - adjustable in 0.1 steps
Distance: - Recorded every 0.125yds
Accuracy < 0.2/yd
Adjustable in steps of 1yd when updating location
Measuring resolution 0.01
Manual Event:- 3 Button text input
Text comment box
Batteries:- Integral rechargeable NiMH
Autonomy:- 20 hours (PDA see manufacturers )
Charging:- Via external 230vac input charging unit (others by request)
Charging Time:- 24 hours for complete charge
Operating Temperature:- 23°F to +104°F
Weight :- 22 lbs.excluding PDA
Size:- Folded for carrying, 43.5 long x 9.85 high x 19.7 wide
Transit Case 47.8 long x 12.6 high x 22.1 wide
Total shipping weight in Transit Case 64lbs