By pressing
A
followed by the the appropriate key, (do not press simultaneously) these special functions and
features can be enabled:
Easy Arm
(when system is disarmed)
The Easy Arm feature allows the system to be armed by
pressing
A followed by 0. This will allow the easy
arming of the system by someone who is not a regular
system user.
Easy Exit
(when system is armed)
This function (if programmed) allows an occupant to leave
the premises without disarming the system. Pressing
A followed by 0 while the system is armed will
start a 3-minute period, during which you can leave through
the Exit/ Entry door.
Bell / Battery Test
Pressing
A
followed by
1
will cause the bell, or
siren to sound for 2 seconds. This will also initiate a test of
your battery to make sure it is adequately charged. The
P800 also performs an automatic battery test every 24
hours.
Access Output
If programmed, pressing
A
followed by
3
will
activate the Access Output which may be configured to
open a door strike, turn on lighting, or activate some other
special feature your installer has provided.
Display System Trouble
Pressing
A
followed by
4
when TROUBLE
H
is lit
will cause the system to display any current system troubles.
Pressing
E will exit the Display System Trouble Mode.
Chime Mode On / Off
Pressing
A followed by 5 will activate / deactivate
the door chime. Activating this feature will cause any door to
beep the keypad sounder when it is opened.
Program Mode
Pressing
A followed by8 will enable the “Program
Mode”, which will allow you to program and erase user
codes. (see Programming user codes, page 14).
Keypad Sounder On / Off
Pressing
A followed by 9 will deactivate / activate
the keypad sounder, depending on its present state. By
deactivating the sounder on a keypad installed in a bedroom,
for example, you will only turn off that keypad’s sounder. All
other keypads on the system will still sound normally.