UNIVERSAL CENTRIFUGE
PLC-012, PLC-012E, PLC-012H
PLC-012BP, PLC-024
!
Safety Information
This manual contains important and safety information.
The user must carefully read and understand the contents of this
manual prior to using this equipment.
2013.0310.1000

Questions and Answers

  • A
    Ariel DownsAug 4, 2025
    Why does the fuse blow always on my Gemmy PLC-012 Laboratory Equipment?
    • S
      Shelley WoodsAug 4, 2025
      If the fuse keeps blowing, you should check and fix the SCR or replace it with a new one. Alternatively, consider replacing the motor, ensuring proper operation, or using a power stabilizer.
  • B
    Brandon RhodesAug 9, 2025
    What to do if my Gemmy PLC-012 is imbalanced?
    • L
      Lauren BeanAug 9, 2025
      To resolve imbalance issues, place the tube diagonally, ensure the rotor and rubber supports are screwed tightly and properly, and correctly position the motor.
  • W
    William TrujilloAug 14, 2025
    How to fix vibration in Gemmy PLC-012 Laboratory Equipment?
    • N
      Nathaniel HerreraAug 14, 2025
      To address vibration problems, try adjusting the rotor or tightening any loose components.
  • R
    rachelthompsonAug 19, 2025
    How to fix broken test tubes in Gemmy PLC-012?
    • B
      Brenda BensonAug 19, 2025
      To prevent test tubes from breaking, ensure they are placed properly and all the way down. Also, make sure to cover the rotor lid correctly. If a tube is already broken, replace it with a new one.
  • D
    David WilliamsAug 25, 2025
    How to fix noise in Gemmy Laboratory Equipment?
    • J
      John SingletonAug 25, 2025
      To reduce noise, try positioning the motor correctly or replacing any worn components with new ones.
  • C
    Christina ChambersAug 29, 2025
    Why is my Gemmy PLC-012 Laboratory Equipment running at erratic speed?
    • C
      Cynthia ReidAug 29, 2025
      If your equipment's speed is erratic, consider replacing the VR or other components.

Summary

Safety Information

Classification and Standards

Centrifuge classified as Class I equipment, compliant with safety and EMC standards.

Product Briefing

Overview of the Class 1 tabletop centrifuge and model variations.

WARNING and Intended Use

BIOHAZARD WARNING

Important warning regarding biohazard use and personal protection.

Product Warning (PLC-024)

Specific warning for PLC-024 model concerning weight and injury risk.

Cautionary Use

Advises against using equipment in ways not specified by manufacturer.

Intended Use

Outlines laboratory applications for which the centrifuge is designed.

Installation Procedures

Definitions

Micro Centrifuge

For volumes up to 2.2ml micro-tubes of DNA precipitations.

Micro Haematocrit Centrifuge

For 24 capillary tubes used in HCT testing.

Universal Centrifuge

Accommodates various rotor sizes and types for different tests.

g Force and RCF

Explains g Force and RCF (Relative Centrifugal Force) calculation.

Rotor and Tube Types

Details Swing-out, Fixed-Angle rotors, and Round/Conical bottom tubes.

Operation Procedures

Basic Operation

Instructions for setting timer, speed, and starting the centrifuge.

Braking and Lid Safety

How to use the brake and the function of the safety lid locking device.

How to use Reading Scale for HCT

How to change rotors

Speed Indicator Calibration

Calibration Procedure

Steps to recalibrate the speed indicator using a tachometer.

Calibration Precautions

Warnings and recommendations for safe and accurate speed calibration.

Disassembly Procedures

Disassembly Steps

Step-by-step guide for taking apart the centrifuge.

Disassembly Safety

Strict warnings and prohibition of disassembly by unqualified personnel.

Maintenance and Servicing

General Maintenance

Procedures like checking rubber supports, motor lubrication, and fuse inspection.

Component Specifics

Notes on carbon brushes, micro-switch, fuse, and F-2415 rotor gasket replacement.

Troubleshooting

Common Problems and Solutions

Table listing common issues like power, speed, vibration, noise, and their corrective actions.

Troubleshooting Notes

Reminders on lubrication, supervision for disassembly, and contacting distributors.

Cleaning, Transportation, and Storage

Cleaning Instructions

Guidelines for cleaning the centrifuge after use, including materials to avoid.

Transportation Guidelines

Precautions for handling and packing the centrifuge for transport.

Storage Conditions

Recommendations for storing the equipment to maintain its condition.

Environmental Conditions for Operation & Storage

Heavy, Risk of Injury

Diagram of Components (PLC-012 Series)

Wiring Diagram (PLC-012)

Wiring Diagram (PLC-012 E, PLC-012 H)

Diagram of Components (PLC-024)

Wiring Diagram (PLC-024)

One Year Limited Warranty

Warranty Coverage

Details product warranty against defects in materials and workmanship.

Warranty Exclusions

Lists conditions not covered by the warranty, such as accident or misuse.

Liability and Claims

Defines Gemmy's liability and how to direct warranty claims.

Gemmy PLC-012 Specifications

General IconGeneral
BrandGemmy
ModelPLC-012
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals