EasyManuals Logo

Genelec 6010A Datasheet

Genelec 6010A
2 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
6010A Data Sheet
Genelec Document BBA0074001. Copyright Genelec Oy 1.2008. All data subject to change without prior notice
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email genelec@genelec.com
In the U.S. please contact:
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, U.S.A.
Phone +1 508 652 0900
Fax +1 508 652 0909
Email genelec.usa@genelec.com
In China please contact:
Genelec China Representative Office
SOHO New Town, 88 Jianguo Road
D-1504, Chaoyang District
Beijing 100022, China
Phone +86 10 8580 2180
Fax +86 10 8580 2181
Amplifier Section
SyStem SpecificAtionS
6010A
Lower cut-off frequency, –3 dB < 73 Hz
Upper cut-off frequency, –3 dB > 21 kHz
Free field frequency response 74 Hz – 18 kHz (± 2.5 dB)
Maximum short term sine wave acoustic
output on axis in half space, averaged from
100 Hz to 3 kHz
@ 1 m > 93 dB SPL93 dB SPL dB SPL
@ 0.5 m > 99 dB SPL99 dB SPL dB SPL
Maximum long term RMS acoustic output
in same conditions with IEC weighted noise
(limited by driver unit protection circuit
@ 1 m > 91 dB SPL
Maximum peak acoustic output per pair with
music material
@ 1 m > 102 dB SPL
Self generated noise level in half space at 1 m
on axis (A-weighted)
< 5 dB
Harmonic distortion at 80 dB SPL
at 1 m on axis
Freq: 70…400 Hz
> 400 Hz> 400 Hz
< 3%
< 0.5 %
Drivers
Bass
Treble
76 mm (3") cone
19 mm (
3
/
4
") metal dome
Weight 1,4 kg (3.1 lb)
Dimensions
Height including Iso-Pod™ table stand
Height without Iso-Pod™ table stand
Width
Depth
195 mm (7
11
/
16
”)
181 mm (7
1
/
8
”)
121 mm (4
3
/
4
")
114 mm (4
1
/
2
”)
6010A
Bass amplifier short term output power
Treble amplifier short term output power
(Long term output power is limited by driver
unit protection circuitry)
12 W at 8 Ohm load8 Ohm load
12 W at 8 Ohm load8 Ohm load
Amplifier system THD at nominal output < 0.08 %
Mains voltage 100, 120, 220 or 230 V
Power consumption (average)
Idle
Full output
5 VA
35 VA
croSSoVer Section
6010A
Signal input connector
RCA female, unbalanced 10 kOhm pin +, ring gnd
Input level for 90 dB SPL output at 1 m -6 dBu at volume
control max
Sensitivity control range -12 dB relative to
max output
Crossover frequency, Bass/Treble 3.0 kHz
Desktop control operating range 0 to –4 dB @ 200 Hz
Bass Tilt control operating range in –2 dB
steps
From 0 to -6 dB @ 100 Hz
The ‘CAL position is with all tone controls set to ‘off and the input sensitivity
control to maximum (fully clockwise).
www.genelec.com
In Sweden please contact
Genelec Sverige
Ellipsvägen 10B
P.O. Box 5521, S-141 05 Huddinge
Phone +46 8 449 5220
Fax +46 8 708 7071
Email info@genelec.com

Other manuals for Genelec 6010A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Genelec 6010A and is the answer not in the manual?

Genelec 6010A Specifications

General IconGeneral
Product colorWhite
Recommended usageOther
Suitable for outdoor use-
TweeterYes
Number of drivers2
Speaker placementTabletop/bookshelf
Audio output channels1.0 channels
Woofer diameter (imperial)3 \
Tweeter diameter (imperial)0.75 \
Impedance- Ω
Sensitivity93 dB
Frequency range73 - 21000 Hz
RMS rated power24 W
Crossover frequency3000 Hz
Total Harmonic Distortion (THD)3 %
Audio RCA inputs1
Connectivity technologyWired
AC input voltage100 - 240 V
Power source typeAC
Weight and Dimensions IconWeight and Dimensions
Depth114 mm
Width121 mm
Height195 mm
Weight1400 g

Related product manuals