EasyManuals Logo

Generac Power Systems PowerDial RS8000E User Manual

Generac Power Systems PowerDial RS8000E
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
6 Owner’s Manual for Portable Generator
Know Your Generator
Replacement owner’s manuals are available
at www.generac.com.
Emissions
The United States Environmental Protection
Agency (US EPA) (and California Air
Resources Board (CARB), for engines/equip-
ment certified to California standards) requires
that this engine/equipment complies with
exhaust and evaporative emissions stan-
dards. Locate the emissions compliance decal
on the engine to determine applicable stan-
dards. For emissions warranty information,
please reference the included emissions war-
ranty. It is important to follow the maintenance
specifications in the manual to ensure that the
engine complies with the applicable emissions
standards for the duration of the product’s life.
Hour Meter
The Hour Meter tracks hours of operation for
scheduled maintenance. See Figure 2-4.
The CHG OIL display will illuminate every
100 hours. The message will flash one hour
before and one hour after each 100 hour
interval, providing a two hour window to
perform service.
The SVC display will illuminate every 100
hours. The message will flash one hour
before and one hour after each 200 hour
interval providing a two hour window to per-
form service.
When the hour meter is in flash alert mode,
the maintenance message will alternate with
elapsed time in hours and tenths. The hours
will flash four times, then alternate with the
maintenance message four times until the
meter automatically resets.
100 hours - CHG OIL Oil Change Inter-
val (Every 100 hrs)
200 hours - SVC Service Air Filter
(Every 200 hrs)
(000100a)
WARNING
Consult Manual. Read and understand manual
completely before using product. Failure to
completely understand manual and product
could result in death or serious injury.
Product Specifications
Generator Specifications
Rated Power @1.0 Power Factor 8.0 kW**
Surge Power 10.0 KVA
Rated AC Voltage 120/240
Rated AC Load
Current @ 240V**
Current @ 120V**
33.3
66.6
Rated Frequency 60 Hz @ 3600 RPM
Phase Single Phase
Weight (dry)
Pounds (lb)
Kilograms (kg)
213.8
97
** Operating Temperature Range: -18 deg. C (0 deg. F) to 40 Deg. C (104 Deg. F). When operated
above 25 deg. C (77 deg. F) there may be a decrease in power.
** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambi-
ent temperature, altitude, engine condition, etc. Maximum power decreases about 3.5% for each
1,000 feet above sea level; and will also decrease about 1% for each C (10° F) above 16° C (60°
F) ambient temperature.
Engine Specifications
Displacement 420cc
Spark Plug Part No. 0J00620106
Spark Plug Gap 0.028-0.031 inch or (0.70-0.80 mm)
Gasoline Capacity 30 L (8 gal)
Oil Type
See Chart in
Add Engine Oil
Oil Capacity 1.0 L (1.06 qt.)
Run Time at 50% Load 10.5 Hours
* Go to
www.generac.com or contact an IASD for replacement parts.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Generac Power Systems PowerDial RS8000E and is the answer not in the manual?

Generac Power Systems PowerDial RS8000E Specifications

General IconGeneral
BrandGenerac Power Systems
ModelPowerDial RS8000E
CategoryPortable Generator
LanguageEnglish

Related product manuals