machine clean.
b. The transmission gear box is packed with
special grease, it could be used for
six m
ouths in normal condition. If it need to add or replace the grease, please
open the top cover , then pour the grease from
aperture or replace the grease
directly.
8、
Problems and solutions
Problems Causes Solutions
The mixing shaft doesn’t rotate
after starting the machine
Electric connectors are
loose
Check the electric
circuit, tighten those
loose connects
Oil leakage The oil seals are worn
out
Replace those oil
seals
Too low voltage Check the power
supply
Over-load Lessen the quantity
of the mixture
The temperature of the motor
becomes higher and the
rotating speed becomes lower
The speed of mixing is
too high or the mixing is
not suitable
Select a suitable
speed and mixing
The mixing knocks with the
bowl
The mixing or the bowl
is deformed
repair or replace the
mixing or bowl
The noise of the gearbox is
serious, its temperature is too
high
Lubrication is
insufficient
Add or replace the
grease