Model No.
Loose (0.75 AC/H)
GPD
Average (0.50 AC/H) Tight (0.30 AC/H)
Elite 570
12
800 sq. ft.
1200 sq. ft.
2000 sq. ft.
Elite 900
17
1115 sq. ft.
1650 sq. ft.
2800 sq. ft.
Elite 1000
18
1175 sq. ft.
1770 sq. ft.
3000 sq. ft.
Outside Design Temp 0° F (-18° C)
Outside Design R.H. 70% R.H.
Inside Design Temp. 70° F (21° C)
Inside Design R.H. 30% R.H.
Air Changes/hour (AC/H) 0.30
Ceiling Height 8 ft
Furnace Plenum Temp. 120° F (49° C)
Furnace run time for 8hr/1 day
calculating sq. ft.
16-3/4”
17”
16-1/2”
ELITE 1000 HUMIDIFIER SPECIFICATIONS
Model 1000A (GFI#5730) includes:
Humidier components: GA19 Vapor pad, Solenoid Assembly, Relay Circuit Board, Fan Motor, Fan Blades
Accessories: GFX3 Automatic Digital Humidistat, Code Valve, Saddle Valve
Model 1000M (GFI#5735) includes:
Humidier Components: GA19 Vapor Pad, Solenoid Assembly, Relay Circuit Board, Fan Motor, Fan Blades
Accessories: Manual Humidstat, Saddle Valve
Expected Humidity Performance Coverage in Square Feet Based on Construction Type
HUMIDIFIER PACKAGED COMPONENT ACCESSORIES
Humidifier Performance Baseline Criteria
Humidier Chassis with plenum
cut out shown as dashed lines
12-1/8”
14-1/8”