If nothing works
The CS141 comes with two possible options if a problem needs to reinitialize the firmware or resetting the device to factory defaults.
If the CS141 does not allow a login or the interface shows a faulty display, but still can be reached regularly, administrators may try the
following:
http: // <IP address> / reboot
This option allows you to force a restart of the CS141 directly.
http: // <IP address> / update
This option takes administrators directly to the update screen without the need for logging in
From now you can select the desired firmware package by drag & drop or by clicking the button. Please note, this function is a rescue
system, the CS141 will reset all settings except the IP address. All configurations are deleted and the device is set to startup
configuration.
Enter the password for the administrator account, if you are not in configuration mode.
The process starts and after successful flashing the standard login screen will be shown.
Note:
If you have lost the administrator password, move the DIP switch to center position. After cold boot, it is possible to flash the device
directly. Enter the following line in your web browser:
http://10.10.10.10/update
As a consequence, the administrative password will be set to default setting.
Starting the rescue system
If this feature is not available, the CS141 offers second option: During flashing, the CS141 saves a complete backup including the
configuration of the “last known: good”.
This version can be activated by setting the following jumper:
If the jumper is set and the adapter boots, CS141 will run this version as a rescue system based on the last firmware version: Inside the
About menu, the firmware version will add the word RESCUE to show its current operational mode.