When fitting measuring cables, keep in mind to grant enough space for the later installation of the BACS module:
As the BACS module among other things provides a built-in temperature sensor the module must attached to the battery in away that
the internal sensor is placed ablut 1-4mm from the battery case. By doing so, the module will be able to measure the air temperature
close to the battery.
Connecting a BC5 measuring cable to terminal ports of batteries at 6V - 16V
When connecting the battery terminals, please observe the torque values specified by the manufacturer, as otherwise you may damage
both the battery and the terminals. Furthermore, please refer the manual of the battery model - depending on the manufacturer, there
may be design differences to the installation examples in this manual.
How to connect the BC4B test cables to 1.2V - 2V bipolar batteries
The BC4B measuring cable provides 4 connectors: two for the positive pole and two for the negative pole. When installing, pay attention
to the color coding as well as the correct connection. Wrong wiring will trigger the measruring cable build-in fuse - the fuse cannot be
repaired or replaced. To avoid damaging the battery as well as the measurement cable, use the torque ratings tested by the according
manufacturer.
How to connect the BC4B test leads to four-pin 1.2V - 2V batteries.
Some manufacturers use batteries with four contact points. Coming witg this design, two contact points are assigned to a positive or
negative pole. Since the BACS measuring cable provvide 4 connectors, they must be fitted accordingly to the battery.