89
Address
Type
Function
Name
Description
Length
110
U
3 / 4
BATTVOLT
Battery Voltage V
1
111
U
3 / 4
INFREQ0
Input Frequency Hz Phase 1
1
112
U
3 / 4
INFREQ1
Input Frequency Hz Phase 2
1
113
U
3 / 4
INFREQ2
Input Frequency Hz Phase 3
1
114
U
3 / 4
CNT_PF
Powerfail Counter
1
115
U
3 / 4
(SNMPALARMS&0x1)
Alarm Battery Bad
1
116
U
3 / 4
(SNMPALARMS&0x2)>>1
Alarm: On Battery
1
117
U
3 / 4
(SNMPALARMS&0x4)>>2
Alarm: Battery Low
1
118
U
3 / 4
(SNMPALARMS&0x8)>>3
Alarm: Battery Depleted
1
119
U
3 / 4
(SNMPALARMS&0x10)>>4
Alarm: Over temperature
1
120
U
3 / 4
(SNMPALARMS&0x20)>>5
Alarm: Input Bad
1
121
U
3 / 4
(SNMPALARMS&0x40)>>6
Alarm: Output Bad
1
122
U
3 / 4
(SNMPALARMS&0x80)>>7
Alarm: Output Overload
1
123
U
3 / 4
(SNMPALARMS&0x100)>>8
Alarm: On Bypass
1
124
U
3 / 4
(SNMPALARMS&0x200)>>9
Alarm: Bypass Bad
1
125
U
3 / 4
(SNMPALARMS&0x400)>>10
Alarm: Output Off as requested.
1
126
U
3 / 4
(SNMPALARMS&0x800)>>11
Alarm: UPS Off as requested.
1
127
U
3 / 4
(SNMPALARMS&0x1000)>>12
Alarm: Charger Failed
1
128
U
3 / 4
(SNMPALARMS&0x2000)>>13
Alarm: UPS Output Off
1
129
U
3 / 4
(SNMPALARMS&0x4000)>>14
Alarm: UPS System Off
1
130
U
3 / 4
(SNMPALARMS&0x8000)>>15
Alarm: Fan Failure
1
131
U
3 / 4
(SNMPALARMS&0x10000)>>1
Alarm: fuse failure
1
132
U
3 / 4
(SNMPALARMS&0x20000)>>1
Alarm: general fault
1
133
U
3 / 4
(SNMPALARMS&0x40000)>>1
Alarm: diagnose test failed
1
134
U
3 / 4
(SNMPALARMS&0x80000)>>1
Alarm: communication lost
1
135
U
3 / 4
(SNMPALARMS&0x100000)>>
Alarm: awaiting power
1
136
U
3 / 4
(SNMPALARMS&0x200000)>>
Alarm: shutdown pending
1
137
U
3 / 4
(SNMPALARMS&0x400000)>>
Alarm: shutdown imminent
1
138
U
3 / 4
(SNMPALARMS&0x800000)>>
Alarm: test in progress
1
139
U
3 / 4
AUX1STATE
AUX Port 1
1
140
U
3 / 4
AUX2STATE
AUX Port 2
1
141
U
3 / 4
AUX3STATE
AUX Port 3
1
142
U
3 / 4
AUX4STATE
AUX Port 4
1
143
U
3 / 4
TEMP1
Sensormanager/SMTCOM sensor 1
1
144
U
3 / 4
TEMP2
Sensormanager/SMTHCOM sensor 2
1
145
U
3 / 4
TEMP3
Sensormanager sensor 3
1
146
U
3 / 4
TEMP4
Sensormanager sensor 4
1
147
U
3 / 4
TEMP5
Sensormanager sensor 5
1
148
U
3 / 4
TEMP6
Sensormanager sensor 6
1
149
U
3 / 4
TEMP7
Sensormanager sensor 7
1
150
U
3 / 4
TEMP8
Sensormanager sensor 8
1
151
U
3 / 4
AEESerModulePresent(1)
Status data, for details contact Effekta
1
152
U
3 / 4
AEESerModulePresent(2)
Status data, for details contact Effekta
1
153
U
3 / 4
AEESerModulePresent(3)
Status data, for details contact Effekta
1
154
U
3 / 4
AEESerModulePresent(4)
Status data, for details contact Effekta
1
155
U
3 / 4
AEESerModulePresent(5)
Status data, for details contact Effekta
1
156
U
3 / 4
AEESerModulePresent(6)
Status data, for details contact Effekta
1
157
U
3 / 4
AEESerModuleError(1,1)
Status data, for details contact Effekta
1
158
U
3 / 4
AEESerModuleError(1,2)
Status data, for details contact Effekta
1
159
U
3 / 4
AEESerModuleError(1,3)
Status data, for details contact Effekta
1
160
U
3 / 4
AEESerModuleError(1,4)
Status data, for details contact Effekta
1