The NTP server in this example is installed on a Windows machine dealing with the IP 192.168.200.17, subnet mask 255.255.255.0.
Both the test PC and the CS141 must therefore be located within the corresponding IP address space.
Otherwise, the NTP server service will not work.
Set up time manually
In some case it may be required to enter time manually. with pressing Set System Time, the CS141 will accept the new values and
overwrite the current system time. The result can be seen instantly under Current System Time. To prevent automatic time correction,
delete NTP Server. Please ensure the UPS does not correct it, too.
Note:
The synchronization with a time server is performed automatically by the operating system inside of the CS141 device. Therefore, you
will not find it in event log files. "Device time synchronized" refers to a special function of the UPS and indicates the internal clock of the
UPS has been readjusted by the CS141.
Exception:
You have changed the settings and restarted the NTP service using the Synchronize with Timeserver function.in this case, the
according user interface subsystem recognizes a manually triggered execution and will insert a log entry.
User management
For this configuration step, navigate to the following menu:
The CS141 provides a preset for 3 user profiles to assign different system privileges:
Settings that do not correspond to the corresponding user profile are hidden as soon as the corresponding user logs on. The user
names as well as the privileges coming with the users are hard-coded by the CS141. Administrators are only allowed to change
passwords:
The administrator
User admin
Default-password: cs141-snmp
Due to its function, the administrator gets the full range of configuration options. The administrator manages network and mail settings.
Furthermore, he is the only user with permission to change the landscape of connected devices.
The technician
User engineer
Default password: engineer
The technician’s user account is restricted to his area of responsibilities - he may access to the functions that relate to technical action.
He has the ability to customize and configure available devices and performs the necessary adjustments.
The customer
User: customer
Default password: customer
The customer has access is restricted to use the system monitors and also viewing as well as downloading a collection of log files -
deleting log files is not possible.