The RCCMD Message
The RCCMD message is a text message that can be defined freely. The text box automatically shifts with the entered text as soon as
you reach the right margin. This message will then appear as an alert on a computer the RCCMD client is installed to. RCCMD also
displays a warning box on the taskbar.
RCCMD Executes
An extensive feature within RCCMD is the possibility to run own executables and batch files on a target computer.
This function is useful if scripts have to be executed right before a shutdown is triggered. It is necessary to move the file to be executed
to the installation directory of the RCCMD client. Afterwards, the CS141 provides to execute this script directly.
Note:
The screenshot shows the command helloworld.bat has been entered. In this case, the RCCMD client on the PC with the IP address
192.168.3.1 would try to start the file hallowelt.bat directly. If you want to use other directories, you need to specify them accordingly:
C:\skript\helloworld.bat
Please note, it is tricky to run a script on a PC that shall trigger scripts on a third device.
RCCMD Traps
RCCMD traps are data packets designed to inform about the current state of the UPS:
A data package is generated, which can be received, read out and interpreted by a corresponding software or device.
The following list contains possible variables that you can use to define RCCMD traps:
#AGENTSOFTREV CS141 Firmware Version
#AUTONOMTIME autonomy time in minutes
#BATT2OLD() time in months until event „Please check batteries“ is triggered
#BATT2OLD_YEARS battery age in years
#BATTCAP battery capacity in %
#BATTINSTDATE installation date of the battery
#BATTTESTDATE date of the last battery test
#BATTVOLT battery voltage in V
#CHARGECURR momentary loading current
#CNT_BL counter battery low
#CNT_PF counter Powerfail
#CNT_SA counter active shutdowns
#CNT_SD counter shutdowns
#CNT_TF counter testing failure
#DATE current date
#EVENTSTATE obstatus (idle, error, progress, success)
#FULLTESTDATE date of the last full battery test
#GETLASTRESULT() last test results
#HOLDTIME hold time at 100 % load
#IDENT_NAME name of the SNMP adapter
#INCURR0/1/2 Eingangsstrom in A
#INFREQ0/1/2 Eingangsfrequenz in Hz
#INPHASES Anzahl Eingangsphasen
#INPUTCURRENT0/1/2 incoming current in A
#INVOLT0/1/2 incoming voltage in V
#LASTERR last error
#LOAD current load
#LOCATION Standort
#MANUFACTURER manufacturer of the UPS
#MODEL UPS model