EasyManua.ls Logo

Genesis STORM - Connecting Components; Sensor and Cable Connections; Tubing and Pump Power Connections

Genesis STORM
11 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
o IfusingyourSTORM™withtheROCv™module,placethe“ROCv™Min”sensorinsideashroud
andaffixittothesideofthebottomshroud,slightlyabovethe“TopOffBin”sensor.Thecord
onthesensorshouldcomeoutofthetopoftheshroud.
4. Connect
theComponents
NOTE:ALLWIRESSHOULDHAVEADRIPLOOPTOPREVENTWATERFROMENTERINGTHECONTROLMODULE
PlugintotheControlModulethelevelsensorharnessthatcontainsthe“Aquarium/Sump”and“TopOffBin”
Sensors.Thisharnessplugsintothe6‐pinreceptacleonthelower
left‐handside(asyouarelookingatthe
backoftheControlModule).
IfusingaROCvmodulewithyourSTORM™system,plugthelevelsensorharnessthatcontainsthe“ROCv
Max”and“ROCvMin”SensorsintotheControlModule.Thisharnessplugsintothe6‐pinreceptacle
onthe
lowerright‐handside(asyouarelookingatthebackoftheControlModule).
Ifused,plugtheaquariumorsump’sFailsafeLevelSensorcableintothe2‐pinreceptacleonthelowerright‐
handside(asyouarelookingatthebackoftheControlModule).
Ifused,plugthetopoffwaterbin’sFailsafeLevelSensorintothe2‐pinreceptacleonthelowerleft‐handside
(asyouarelookingatthebackoftheControlModule).
IfcouplingyourSTORM™systemwithaRENEWautomaticwaterchangesystem(seeourwebsite
forwhyyou
wanttodothis!),plugthecommunicationharnesssuppliedwiththeRENEWsystemintothecenter6‐pin
receptacleonthebackoftheSTORM™ControlModule,andplugtheotherendintothecenter6‐pin
receptacleonthebackoftheRENEWControlModule.
5.
Attachasegmentofappropriatelysizednon‐toxictubingtoasubmersiblepumpandplacethepumpinthetopoffwater
bin.
6. Routethetubing totheaquariumorsump.Thetubingshouldbesecuredsuchthattheendofthetubingisjust above
thehighestwater
levelintheintheaquariumorsump,sothatthewaterwillrundownthesideofthetankasthewater
leveldrops.Doingsowillimprovewaterflow,reducenoise,andpreventwaterfromsiphoningbackintothetopoffbin.
Cutthetubingtolengthifnecessary.
7. Plugthepump’spowercordintotheACreceptacleonthebottomrightoftheControlModule(whenviewingthefrontof
theControlModule).EnsurethatadriploopisformedtopreventwaterfromenteringtheControlModule!
8. PlugtheControlModule’spowercordinto
aGFCI‐protected110VACoutlet.Ensurethatadriploopisformedtoprevent
waterfromenteringtheControlModule!YouarenowreadytouseyourSTORM™System!