EasyManua.ls Logo

Genesis STORM - Connecting Components; Sensor and Cable Connections; Tubing and Pump Power Connections

Genesis STORM
11 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
o IfusingyourSTORM™withtheROCv™module,placethe“ROCv™Min”sensorinsideashroud
andaffixittothesideofthebottomshroud,slightlyabovethe“TopOffBin”sensor.Thecord
onthesensorshouldcomeoutofthetopoftheshroud.
4. Connect
theComponents
NOTE:ALLWIRESSHOULDHAVEADRIPLOOPTOPREVENTWATERFROMENTERINGTHECONTROLMODULE
PlugintotheControlModulethelevelsensorharnessthatcontainsthe“Aquarium/Sump”and“TopOffBin”
Sensors.Thisharnessplugsintothe6pinreceptacleonthelower
lefthandside(asyouarelookingatthe
backoftheControlModule).
IfusingaROCvmodulewithyourSTORM™system,plugthelevelsensorharnessthatcontainsthe“ROCv
Max”and“ROCvMin”SensorsintotheControlModule.Thisharnessplugsintothe6pinreceptacle
onthe
lowerrighthandside(asyouarelookingatthebackoftheControlModule).
Ifused,plugtheaquariumorsump’sFailsafeLevelSensorcableintothe2pinreceptacleonthelowerright
handside(asyouarelookingatthebackoftheControlModule).
Ifused,plugthetopoffwaterbin’sFailsafeLevelSensorintothe2pinreceptacleonthelowerlefthandside
(asyouarelookingatthebackoftheControlModule).
IfcouplingyourSTORM™systemwithaRENEWautomaticwaterchangesystem(seeourwebsite
forwhyyou
wanttodothis!),plugthecommunicationharnesssuppliedwiththeRENEWsystemintothecenter6pin
receptacleonthebackoftheSTORM™ControlModule,andplugtheotherendintothecenter6pin
receptacleonthebackoftheRENEWControlModule.
5.
Attachasegmentofappropriatelysizednontoxictubingtoasubmersiblepumpandplacethepumpinthetopoffwater
bin.
6. Routethetubing totheaquariumorsump.Thetubingshouldbesecuredsuchthattheendofthetubingisjust above
thehighestwater
levelintheintheaquariumorsump,sothatthewaterwillrundownthesideofthetankasthewater
leveldrops.Doingsowillimprovewaterflow,reducenoise,andpreventwaterfromsiphoningbackintothetopoffbin.
Cutthetubingtolengthifnecessary.
7. Plugthepump’spowercordintotheACreceptacleonthebottomrightoftheControlModule(whenviewingthefrontof
theControlModule).EnsurethatadriploopisformedtopreventwaterfromenteringtheControlModule!
8. PlugtheControlModule’spowercordinto
aGFCIprotected110VACoutlet.Ensurethatadriploopisformedtoprevent
waterfromenteringtheControlModule!YouarenowreadytouseyourSTORM™System!