5. Whenthemaximumdesiredwaterlevelisachieved,simplypressthePAUSE/RESETbuttonforalasttime.You’redone!
Thenumberofsecondsittooktoraisethewaterlevelfromtheminimumdesiredleveltoyouridealwaterlevelis
automaticallystored.Thenexttimethewater
leveldropstotheLevelSensor,thepumpwillbeturnedonandwillrun
forthesameamountoftime,therebyaddingthesameamountofwatertoyouraquariumorsump.Ifthereisevera
needtoadjustthenumberofsecondsmanually,simplypresstheINCREASE
orDECREASEbuttonsindividuallytoaddor
removeafewsecondsfromthecycle.
InterruptingandResumingtheTopOffandAuxiliaryFunctions
IfyoueverneedtosuspendthetopofffunctionofyourSTORM™system,simplypressandreleasethePAUSE/RESETbutton.The
“MONITORING”and“TOPPINGOFF”indicatorswillblinktoindicatethatthetopofffunctionispaused.Toresume,simplypressand
releasethebuttonagain.Note
thatpausingthetopofffunctionwillNOTaffecttheauxiliarymode.Inordertosuspendtheauxiliary
functions,simplydepresstheAUXbuttonuntilthe“OFF”indicatorisilluminated.
InteractionwiththeGenesisRENEW™AutomaticWaterChangeSystem
YourSTORM™canbeconnectedtoaGenesisRENEW™AutomaticWaterChangeSystemtoallowbothunitstobeinstalledinan
aquariumsystemandworktogetherwithoutmanuallydisablingtheSTORM™.TheSTORM™willnotattempttotopoffthesumpor
aquariumanytimetheRENEW™unitis
activelyperformingawaterchangecycle.ThispreventstheSTORM™fromattemptingto
replacethewastesaltwaterremovedbytheRENEW™systemwithfreshwater.Doingsowouldadverselyaffectsalinityina
saltwateraquariumandcouldeventuallyresultinoverflowingthesumpineitherafreshwaterorsaltwateraquarium.When
thetop
offfunctionshavebeendisabledbytheRENEW™system,theLEDindicatoronthelowerrightoftheSTORM’s™ControlModulewill
illuminatetoindicatethattheyhavebeensuspended,andthe“MONITORING”indicatorwillnotbeilluminated.