16
ENGLISH
(1) If maintained, it prolongs the pause until disabled by the command (timer function)
(2) If remaining pause time is shorter than 5 sec., when safety devices are released, it closes after 5 sec.
NB.: Effects on other active pulse inputs in brackets.
CLOSED
LOGIC "EP"
PULSES
GATE STATUS
OPEN-A
OPEN-B
STOP
OPENING SAFETY DEVICES
CLOSING SAFETY DEVICES OP/CLOS. SAFETY DEVICE
Opens the free leaf
Opens the leaves
No effect (OPEN disabled)
No effect
No effect (OPEN disabled)
OPEN
Re-closes the leaf/leaves immediately
No effect (OPEN disabled)
AT CLOSING
Stops operation see paragraph 5.2
.
Locks and, on release, reverses at opening
AT OPENING
Stops operation
Stops operation
Reverses at closing No effect
Locks and, on release, continues opening
No effect
(if it must close, it disables OPEN)
LOCKED
Restarts moving in reverse direction
(always closes after a Stop )
No effect (OPEN disabled) No effect (if it must open, it disables OPEN)
No effect (OPEN disabled)
No effect (OPEN disabled)
Table 3/d
No effect (saves OPEN)
CLOSED
OPEN
AT CLOSING
No effect
(OPEN-A/B disabled)
Opens the leaf or leaves
LOCKED
AT OPENING
No effect
LOGIC "B"
GATE STATUS
OPEN-A
No effect
(OPEN-A disabled)
No effect (OPEN-B disabled)
No effect
(OPEN-A disabled)
OP/CLOS. SAFETY DEVICE
CLOSING SAFETY DEVICESOPENING SAFETY DEVICES
STOP
OPEN-B
Stops operation
(OPEN-A/B disabled)
No effect
Opens the leaf or leaves
No effect
Reverses at opening
No effect
No effect
(OPEN-A disabled)
No effect
(OPEN-B disabled)
No effect
(OPEN-A/B disabled)
Table 3/e
Closes the leaves or leaf
No effect
No effect
Closes the leaves or leaf
Stops operation
No effect
(OPEN-B disabled)
No effect
(OPEN-A disabled)
No effect
PULSES
No effect
(OPEN-B disabled)
Stops operation
(OPEN-B disabled)
Stops operation
(OPEN-A/B disabled)
No effect
(OPEN-B disabled)
No effect
(OPEN-A disabled)
No effect
(OPEN-A disabled)
CLOSED
OPEN
AT CLOSING
AT OPENING
LOGIC "C"
GATE STATUS
OPEN-A
OP/CLOS. SAFETY DEVICE
CLOSING SAFETY DEVICESOPENING SAFETY DEVICES
STOP
OPEN-B
Stops operation
(OPEN-A/B disabled)
No effect
Opens the leaf or leaves
No effect
Stops operation
No effect
Stops operation
(OPEN-A disabled)
No effect
(OPEN-B disabled)
Closes the leaves or leaf
Stops operation
Stops operation
No effect
(OPEN-A disabled)
No effect
COMMANDS ALWAYS PRESSED
No effect
(OPEN-B disabled)
No effect
(OPEN-B disabled)
No effect
(OPEN-A disabled)
No effect
(OPEN-A disabled)
No effect
(OPEN-A disabled)
No effect
(OPEN-B disabled)
Stops operation
(OPEN-A/B disabled)
Stops operation
(OPEN-B disabled)
Table 3/f