Explains different power ratings like ESP, PRP, LTP, and COP used for generators.
Provides guidance on generator load conditions, minimum load, and synchronization.
General overview of generator safety and responsible usage practices.
Lists critical safety prohibitions for fuel handling, operation, and maintenance.
Advises on essential actions for battery maintenance and general care.
Safety precautions when interacting with moving parts and hazardous materials.
Safety guidelines related to toxic exhaust fumes and proper ventilation.
General guidance on electrical safety and emergency first aid procedures.
Lists key features of Genpower's air-cooled diesel generators.
Explains the oil level sensor and recommends 15W40 oil for the generator.
Describes the purpose of the identification plate for parts and service.
Advises on using high-quality detergent oils and proper viscosity selection.
Step-by-step instructions for filling the generator with engine oil.
Procedure for checking the engine oil level using the dipstick.
Guidelines for using clean, filtered diesel fuel.
Tips for optimal generator performance and longevity.
Step-by-step guide for starting the generator, including key, lever, and switch operations.
Actions after starting and steps if the engine does not start.
Instructions on applying loads, managing overload, and output voltage.
Information on battery charging and safety precautions during connection.
Steps to properly shut down the generator after use, including cool-down.
Overview of general maintenance and authorized service requirements.
Frequency and method for regularly checking engine oil levels.
Procedures and intervals for changing engine oil.
Instructions for inspecting, cleaning, and replacing the air filter.
Guidelines for cleaning and maintaining the fuel filter.
Methods for cleaning the generator exterior and ensuring airflow.
Preparations needed for storing the generator for extended periods.
Provides a schedule for routine maintenance tasks.
Common causes and responsive actions for when the genset does not start.
Common causes and responsive actions for when the genset does not generate power.
The GENPOWER GDG SERIES is a range of diesel portable generators designed for various applications, offering reliable power generation with a focus on durability, efficiency, and user-friendliness. These generators are manufactured in compliance with international standards such as ISO 9001:2000 and ISO 14001:2004, ensuring high quality and environmental compatibility.
The primary function of the GENPOWER GDG SERIES generators is to provide a portable source of electrical power, particularly in situations where a reliable utility power supply is unavailable or unreliable. These units are designed to convert the mechanical energy from a diesel engine into electrical energy, making them suitable for both standby and prime power applications. The generators are equipped with advanced technology diesel engines and high-quality alternators, ensuring efficient and stable power output. They feature a direct fuel injection system and an automatic voltage stabilizer (AVR) to maintain consistent voltage levels, crucial for protecting connected devices. The GDG series also includes safety features such as a low oil pressure alarm and circuit protectors (NFB) to prevent damage to the engine and electrical components. The generators are designed to operate under heavy-duty conditions, with a tropical 50 °C radiator for effective cooling and a compact, silent, patented design canopy that reduces noise levels, making them suitable for use in various environments.
The GENPOWER GDG SERIES generators are designed for ease of use, though careful adherence to the operating manual is essential for safe and efficient operation. Before starting, users must ensure the generator is placed on a flat surface and that the oil tank is filled to the appropriate level, as the generators are shipped without oil. The recommended oil type is 15W40, and users should regularly check the oil level using the dipstick. The fuel system requires light, clean diesel fuel, and it's crucial to avoid overfilling the tank or allowing dust and water to mix with the fuel.
Starting the generator involves a few key steps: inserting the key into the start switch and turning it to the "OFF" position, moving the speed lever to the "RUN" position, and then turning the start switch clockwise to the "START" position. For silent type generators, an intermediate "RUN" (ON) position is used for 1-2 seconds to trigger the electromagnetic iron before moving to "START." It is critical that the circuit breaker is in the "OFF" position before starting to prevent dangerous situations, and the generator should always be grounded to prevent electric shock. If the engine doesn't start after 10 seconds of cranking, a 15-second wait is recommended before trying again to avoid draining the battery.
When connecting loads, it's advised to start with larger loads first and then add smaller ones, ensuring the total load does not exceed the generator's maximum output power. The voltmeter should be observed to ensure the output voltage is within the specified range (230V/400V±5% for 50Hz or 240V±5% for 60Hz). The generator's speed can be adjusted via the speed governor to achieve the desired frequency (50/60Hz). For generators with an electric starter, the 12V battery is automatically charged when the engine is running. For prolonged storage, the battery should be disconnected to prevent energy loss.
Stopping the generator involves disconnecting all loads, allowing the engine to run for 3 minutes in the "RUN" position after unloading to cool down gradually, and then turning the key switch to the "OFF" position. Abrupt shutdowns can lead to abnormal engine temperatures and potential damage.
Regular maintenance is crucial for the longevity and optimal performance of the GENPOWER GDG SERIES generators. The manual outlines a comprehensive maintenance schedule, emphasizing daily checks, monthly, quarterly, semi-annual, and annual tasks. Key maintenance activities include:
For long-term storage, specific preparations include running the engine for 3 minutes, changing the engine oil while hot, adding lubricating oil to the cylinder head, and cranking the engine for a few seconds with the decompression handle down (without starting) to distribute the oil. The genset should then be cleaned and stored in a dry place.
The manual strongly advises against unauthorized repairs or maintenance, as this will void the guarantee. Users are encouraged to utilize authorized services and original spare parts for all maintenance and repair needs. Safety measures, such as disconnecting the spark plug wire and accumulator terminals before servicing, are emphasized to prevent accidental starts and ensure user safety.
| Type | Portable Generator |
|---|---|
| Fuel Type | Gasoline |
| DC Output | 12V |
| Model | GDG Series |
| Engine Type | 4-stroke, OHV |
| Starting System | Recoil start |
| AC Output | 120V |