DIESEL PORTABLE GENERATORS
USER AND MAINTENANCE MANUEL
GDG SERIES
Question and Answer IconNeed help?

Do you have a question about the GENPOWER GDG Series and is the answer not in the manual?

Summary

Important General Information

Generator Rating Definitions

Explains different power ratings like ESP, PRP, LTP, and COP used for generators.

Selection and Operation Recommendations

Provides guidance on generator load conditions, minimum load, and synchronization.

Safety Measures

1.1. Introduction to Safety

General overview of generator safety and responsible usage practices.

1.2. Prohibited Actions

Lists critical safety prohibitions for fuel handling, operation, and maintenance.

1.3. Recommended Actions

Advises on essential actions for battery maintenance and general care.

1.4. Moving Parts and Materials Safety

Safety precautions when interacting with moving parts and hazardous materials.

1.5. Exhaust Gas Safety

Safety guidelines related to toxic exhaust fumes and proper ventilation.

1.6. Electrical Safety and First Aid

General guidance on electrical safety and emergency first aid procedures.

Before Starting

Features of Air-Cooled Diesel Generators

Lists key features of Genpower's air-cooled diesel generators.

Oil Level Sensor and Oil Type

Explains the oil level sensor and recommends 15W40 oil for the generator.

Generator Identification Plate

Describes the purpose of the identification plate for parts and service.

Recommended Engine Oil

Advises on using high-quality detergent oils and proper viscosity selection.

2.1. Filling Oil

Step-by-step instructions for filling the generator with engine oil.

2.2. Checking the Oil Level

Procedure for checking the engine oil level using the dipstick.

2.3. Diesel Fuel Recommendations

Guidelines for using clean, filtered diesel fuel.

2.4. Recommendations for Efficient Performance

Tips for optimal generator performance and longevity.

Main Parts of the Generator

Starting and Operating the Generator

4.1. Starting Procedure

Step-by-step guide for starting the generator, including key, lever, and switch operations.

4.2. Post-Start and Troubleshooting

Actions after starting and steps if the engine does not start.

4.3. Loading the Generator

Instructions on applying loads, managing overload, and output voltage.

4.4. Battery Charging

Information on battery charging and safety precautions during connection.

Stopping the Generator

5.1. Stopping Procedure

Steps to properly shut down the generator after use, including cool-down.

Maintenance

6.1. General Maintenance Guidelines

Overview of general maintenance and authorized service requirements.

6.2. Check Oil Level Regularly

Frequency and method for regularly checking engine oil levels.

6.3. Oil Change

Procedures and intervals for changing engine oil.

6.4. Air Filter Maintenance

Instructions for inspecting, cleaning, and replacing the air filter.

6.5. Fuel Filter Maintenance

Guidelines for cleaning and maintaining the fuel filter.

6.6. Cleaning of Generator

Methods for cleaning the generator exterior and ensuring airflow.

6.7. Storing for Long Periods

Preparations needed for storing the generator for extended periods.

6.8. Example Maintenance Schedule

Provides a schedule for routine maintenance tasks.

Troubleshooting

Genset Not Started Issues

Common causes and responsive actions for when the genset does not start.

Genset Not Generating Issues

Common causes and responsive actions for when the genset does not generate power.

Overview

The GENPOWER GDG SERIES is a range of diesel portable generators designed for various applications, offering reliable power generation with a focus on durability, efficiency, and user-friendliness. These generators are manufactured in compliance with international standards such as ISO 9001:2000 and ISO 14001:2004, ensuring high quality and environmental compatibility.

Function Description

The primary function of the GENPOWER GDG SERIES generators is to provide a portable source of electrical power, particularly in situations where a reliable utility power supply is unavailable or unreliable. These units are designed to convert the mechanical energy from a diesel engine into electrical energy, making them suitable for both standby and prime power applications. The generators are equipped with advanced technology diesel engines and high-quality alternators, ensuring efficient and stable power output. They feature a direct fuel injection system and an automatic voltage stabilizer (AVR) to maintain consistent voltage levels, crucial for protecting connected devices. The GDG series also includes safety features such as a low oil pressure alarm and circuit protectors (NFB) to prevent damage to the engine and electrical components. The generators are designed to operate under heavy-duty conditions, with a tropical 50 °C radiator for effective cooling and a compact, silent, patented design canopy that reduces noise levels, making them suitable for use in various environments.

Usage Features

The GENPOWER GDG SERIES generators are designed for ease of use, though careful adherence to the operating manual is essential for safe and efficient operation. Before starting, users must ensure the generator is placed on a flat surface and that the oil tank is filled to the appropriate level, as the generators are shipped without oil. The recommended oil type is 15W40, and users should regularly check the oil level using the dipstick. The fuel system requires light, clean diesel fuel, and it's crucial to avoid overfilling the tank or allowing dust and water to mix with the fuel.

Starting the generator involves a few key steps: inserting the key into the start switch and turning it to the "OFF" position, moving the speed lever to the "RUN" position, and then turning the start switch clockwise to the "START" position. For silent type generators, an intermediate "RUN" (ON) position is used for 1-2 seconds to trigger the electromagnetic iron before moving to "START." It is critical that the circuit breaker is in the "OFF" position before starting to prevent dangerous situations, and the generator should always be grounded to prevent electric shock. If the engine doesn't start after 10 seconds of cranking, a 15-second wait is recommended before trying again to avoid draining the battery.

When connecting loads, it's advised to start with larger loads first and then add smaller ones, ensuring the total load does not exceed the generator's maximum output power. The voltmeter should be observed to ensure the output voltage is within the specified range (230V/400V±5% for 50Hz or 240V±5% for 60Hz). The generator's speed can be adjusted via the speed governor to achieve the desired frequency (50/60Hz). For generators with an electric starter, the 12V battery is automatically charged when the engine is running. For prolonged storage, the battery should be disconnected to prevent energy loss.

Stopping the generator involves disconnecting all loads, allowing the engine to run for 3 minutes in the "RUN" position after unloading to cool down gradually, and then turning the key switch to the "OFF" position. Abrupt shutdowns can lead to abnormal engine temperatures and potential damage.

Maintenance Features

Regular maintenance is crucial for the longevity and optimal performance of the GENPOWER GDG SERIES generators. The manual outlines a comprehensive maintenance schedule, emphasizing daily checks, monthly, quarterly, semi-annual, and annual tasks. Key maintenance activities include:

  • Oil Check and Change: The oil level should be checked daily or every 5 hours of operation. Oil changes are recommended after the first 5 hours of use, then every 50 working hours under normal conditions, or every 25 hours under high temperatures and loads. Draining the oil when the engine is warm is easier and more effective.
  • Air Filter Maintenance: The air filter should be cleaned every 500 hours or 6 months and replaced if necessary, especially if engine performance decreases or exhaust gases are discolored. It's vital never to operate the engine without the air filter to prevent foreign objects from entering the intake system and causing severe damage.
  • Fuel Filter Maintenance: The fuel filter should be cleaned every 3 months or 100 hours to ensure maximum performance. This involves draining fuel from the tank, removing the filter, and cleaning it with diesel fuel. The fuel injector should also be cleaned of carbon deposits.
  • Generator Cleaning: The generator should be kept free of dirt and debris using a cloth or brush. Water jet washing is not recommended due to potential damage to the fuel system, alternator winding, and electrical equipment. Air ducts on the engine body and alternator air outlet windows must be kept open and clean to ensure proper cooling. The starter guard area should also be cleaned every 100 hours or season.
  • Battery Maintenance: For accumulator-started generators, regular battery maintenance and cleaning are essential. The battery electrolyte level should be checked and kept clean. Users are warned about the corrosive nature of accumulator acid and the flammable gases produced during charging.
  • Valve Clearance and Cylinder Cover Wash: These are annual checks and adjustments to ensure the engine operates efficiently.
  • Fuel Tank Replacement: The fuel tank is recommended to be replaced every 3 years.

For long-term storage, specific preparations include running the engine for 3 minutes, changing the engine oil while hot, adding lubricating oil to the cylinder head, and cranking the engine for a few seconds with the decompression handle down (without starting) to distribute the oil. The genset should then be cleaned and stored in a dry place.

The manual strongly advises against unauthorized repairs or maintenance, as this will void the guarantee. Users are encouraged to utilize authorized services and original spare parts for all maintenance and repair needs. Safety measures, such as disconnecting the spark plug wire and accumulator terminals before servicing, are emphasized to prevent accidental starts and ensure user safety.

GENPOWER GDG Series Specifications

General IconGeneral
TypePortable Generator
Fuel TypeGasoline
DC Output12V
ModelGDG Series
Engine Type4-stroke, OHV
Starting SystemRecoil start
AC Output120V