Common causes;
1. Lamps are replaced without first disconnecting the unit from the electrical
supply.
2. Unit is exposed to extreme wet conditions.
3. Electrical supply power surge occurred in the building.
The unit must be reset to resume normal operation.
RESETTING THE LAMP CIRCUIT
If lamps do not light after replacement, reset the circuit as follows:
Isolate/disconnect the unit from the electrical supply.
Wait for 15 seconds, a faint glimmer may occur in either or both lamps
indicating the circuit has reset.
Reconnect the unit to the electrical supply.
ACTION IN CASE OF FAILURE
In the unlikely event of failure, should the lamps fail to light please have the
supply circuit and fuses checked by a qualified electrician.
If the lamps and electrical supply are in order but the unit still does not
function, please contact the local distributor.
Your local distributor will be able to supply any parts and replacement UV
lamps.