EASY BROKEN PARTS: SEALS, FILTER
SP 250 E
Dimension(mm)
440*285*620
Net weight
9.4Kgs
Tank capacity
25L
Working pressure
(Mpa)
1
Pump type
diaphragm
Stroke
1.4mm
Voltage
12V
Battery
12V/12AH
Troubleshooting
Problem*
Cause
solutions
The motor foil» to start after being
powered on
5. The power cable« come off,
6. The battery was out of power
7. The power switch ha» been damaged.
8. The battery it too hot. the protection switch turn
down.
3. Dismantle the base to connect the cable.
4. Chargeing
3 replace the switch
4 Use after battery cooling
No spraying water or (spraying
pressure is not stable
1 .Nozzle was blocked
4. There is air in the pipe.
5. The pump was blocked Suction
6. hose cracked
1 .Take nozzle down and clean
4. Tighten the connection and discharge air
5. Disassemble the pump and clean the
foreign matters
4 . Replace the tube
Output and pressure come down
4. The inlet niter was blocked
5. The switch filter was blocked
6. Low battery voltage
1 Clean the filter
4. Clean the filter
5. Charging
Leakage
4. The connection is not tight
5. Gasket is broken
6. The inlet and outlet hose of pump cracked
4. Tighten the screw
5. Replace the gasket
6. Replace the hose
Poor atomization
1. The spraying hole was clogged
2. Spraying hole and split sheet wore out
3. Spraying sheet inversely mounted
4. Filter screen was clogged
5. Leakage occurred to tubes at joints
6. Battery short of power
7. Air remained in the pump
1. Remove foreign matters
2. Replace the spraying sheet and split
sheet
3. Correct
4. Clean
5. Tighten
6. The alarm out of order, replace it.
charge
7. Remove the nozzle or spraying rod to
discharge the air
Abnormal sound heard in the motor
The fastening screws of pump loose
Tighten the screw