NO POWER UP
Description:
·
Verify plotter is plugged.
· Verify the voltage in the power supply is 29.5V (between V+ and V-).
· Verify the Voltages in the masterboard:
-Voltage 29.5V between TP1 and TP2.
-Voltage 5V between TP1 and TP3.
-Voltage 3.3V between TP1 and TP4.
-Voltage 1.8V between TP1 and TP5.
· Check Power Line Sensor LED is green.
· If necessary, adjust potentiometer to 29.5V (between V+ and V-).
· Check input voltage is between ranges 84 - 264V (between N and L).