TAG CORRUPTED
PLOTTER BUSY
INVALID CODE
Plotter TAG has corrupted information that doesn't allows to work.
Contact service to get the code to format it.
Plotter can not execute the required action due another action is in process.
1. Wait until the current action has nished to start the next one
An invalid code has been introduced on the plotter.
1. Verify that the code has been introduced correctly.
TAG FAILURE
Description:
Description:
0.
Restart machine.
1. Check cable connected CON29.
2. Check RED LED 5 (bottom one), it must be blinking.
If it is not blinking, load the rmware using the PICkit on the CON17. After
it, if it is not blinking contact Service.
3. When it turns on, GREEN LED blinks two times quickly, during
initialization. After this sequence the green LED should do a short and a
long sequence. If it's not:
3.1 - Disconnect CON29.
3.2 - Measure 6 ohms between indicated pins.
3.3 - Contact service.
Plotter cannot read/write internal TAG. Critical information is not accesible to start-up.
Description: