52
1) If the issue moves to PH2 ( ), the issue can come from the small at cables or the cartridge
control board.
1.1) Replace the PH1 small at cables and reconnect it as original position.
1.2) If after replacing the small at cable, the issue is on PH1( ),
replace the cartridge control board
2) If the issue, still on PH1 ( ), the problem can be on the long at cables, carriage board or
master board.
Follow next steps
CARTRIDGE NOT DETECTED - 4PH
3�
RESEAT ALL CABLES
4� CROSS SMALL FLAT CABLES PH1 AND PH2
5� BACK TO ORIGINAL POSITION
1
1
2
2
3
3
4
4
If error persist, follow next steps.
Don’t manipulate flat cables with the plotter powered.
1
5
Turn off the plotter and
wait until all led's are
totally off.
Turn off the plotter.
Turn off the plotter.
Disconnect at cables from the
carriage board
Swap print head board at cables.
Reconnect CON8, CON9,
CON10 cables of master
board.
CON8
CON9
CON10
PH1 PH1
PH2 PH2
Reconnect small at cable of
print head board.
Reconnect big at cables of
print head board.
Turn on the plotter.
Turn on the plotter.
Turn on the plotter.
32 4