In case of MP+ UPGRADE KIT or MP+:
MP Maintenance Tools is NOT suported on MP+ plotters.
DO NOT install rmware versions previous to version 6.1.1.22. It can provoque an unrecoverable
situation in case of a failed update. On these cases a pre-programmed PicKit will be neded to
recover and reinstall fw on the corrupted modules of the plotter.
85
2 - Remove the micro SD card of
the master board.
(Only class 4 is allowed).
3 - Connect it to the PC using a
micro SD card adapter.
6 - Insert the micro SD card in the
master board again.
FIRMWARE INSTALLATION
OPTION 1: SD card full installation.
4 -
Make a fast quick format
FAT32.
1 - Turn off the plotter.
5 - Load the content of the
rmware release folder to the
SD card.