EasyManua.ls Logo

German pool EFB-PCTH - Battery Replacement

German pool EFB-PCTH
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P.14 P.15
Operating Instructions Cleaning & Maintenance
WARNING!
DO NOT wash HEPA lter with water or any liquid. DO NOT immerse HEPA lter in water.
DO NOT place this product and HEPA Filter in humid area that the lter is moist and wet condition.
Thermostat Function Instruction (Warm Air Mode)
1. Press the “Warm Air Mode” button and the LED Display shows the ambient
temperature.
2. Press “+
-”button, temperature display on LED Display will flash, and user can
set A desired temperature ( 1-30°C).
3. 10 seconds after the desired temperature is set, LED Display will stop flashing,
and show ambient temperature.
• The temperature being set should be higher than the ambient temperature, so
that the heating function will be turned on.
• When the ambient temperature reaches the set temperature, the heating
function will stop, the product will continue to run for 40 seconds, then return to
Standby Mode.
• When ambient temperature drops lower than the set temperature, the heating
function will automatically be reactivated.
Attention:
The factory default temperature is set at 25°C.
After the Warm Air Mode has run for over 9 hours, the product will
automatically stop running. Restart by pressing the On/Off Button on the
main body or the Remote Control.
WARNING!
Unplug the power supply before
performing maintenance.
1. Lift out Top Cover.
3. Install new filter into the main body
of the product.
4. Reinstall Top Cover, the magnetic lid
will snap into place automatically.
2. Lift out the old air filter.
Filter Replacement