FILTERING MATERIALS AND CARTRIDGES
is made of polypropylene (PFM, РР, PPY). It removes dirt, suspended
solids and insoluble impurities >5 µm from water
Aragon is micro-porous ion-exchange polymer. It removes a wide range of harmful
impurities from water: hardness salts, iron, manganese, heavy metals, chlorine, solids and
organic compounds.
Aragon is recommended for areas having water with high iron content. It contains special
material for iron removal and pH correction.
Aragon S is a cartridge for soft water. It removes harmful impurities fully and in addition
it saves healthy calcium salts. Moreover, a micro-element batcher B(Ca) can be mounted
into Aragon S.
Aragon 2 is a cartridge for hard and ferriginous water. This compound Aragon- and
ion-exchange-based cartridge increases the capacity for removal of hardness salts,
manganese, iron (saluted and colloidal), heavy metals (cadmium, lead, etc.) signicantly.
BAF cartridge
contains multi-component media on the basis of sorbents and ion-
exchange materials. It removes chlorine and organic impurities from water, reduces heavy
metals content.
BS cartridge is for hard water. It contains ion-exchange resin of drinking class to soften
water (to remove hardness salts). This cartridge is movable and can be re-used after
regeneration (recovery of ltering properties) many a time.
BA cartridge is for water with high iron content (ferriginous). Into a cartridge there is
catalytic media (calcspar) for saluted and suspended iron removal from water. It reduces
water pH, hastens oxidation process of saluted iron and other metal compounds. So that,
appeared residual matter is kept inside a cartridge.
MAJOR CONTAMINANTS PURIFICATION EFFICIENCY
Suspended solids > 0.4 µm (rust, sand, algae, other insoluble particles ) 100%
Heavy and radioactive metals (lead, cadmium, copper, strontium-90, cesium) up to 99%
Chlorine up to 99%
Organic up to 92%
Hardness salt up to 85%
Microorganisms and E.coli 99%
CARTRIDGES AVERAGE LIFETIME AND CAPACITY
Cartridge  
РР, РРY, PFM 12 up to 7000
Aragon-S 12 up to 7000
Aragon 2 12 up to 7000**
Aragon 12 up to 7000**
BS 12 up to 4000**
BAF 18 up to 12000**
BA 6-8 up to 2000**
*
depends on the level of source water contamination
**
in case the hardness is up to 3 mg-eq/l, iron content is up to 1 mg/l in water