Further installation situationsGC 339
9 Further installation situations
9.1 Single leaf installation and separate activation
Installation height Distance between
detector and HSK
Max. leaf width* Detection width DIN
18650/EN 16005
2000 0 1150 2000
2200 100 1350 2200
2500 250 1650 2500
3000 500 1900 2500 / 3000
3500 750 2150 2500 / 3000
* When only one GC 339 detector is used. If necessary, a GC 339 with a different
frequency is required for further protection.
1
2
3
4
5
6
1 Distance
2 HSK
3 Installation height
4 Protection; 2 m height accord-
ing to DIN 18650 / EN 16005
5 Leaf width
6 Detection width