38(1 1/2")
MANUFACTURER'S STATEMENT
DETECTION AREA
OUTER DIMENSIONS AND PART NAMES
ENGLISH
5922710 JAN 2015
NI-0042-1
(1) Connector
(2) Mounting holes
(3) Operation indicator
(4) Width adjustment screws
(5) Depth angle adjustment screw
(6) Function switch
(7) Radar sensitivity potentiometer
(8) DIP-switches
(9) Detection window
(10) Area adjustment tool
Model
Cover color
Mounting height
Detection area
Detection method
Depth angle
adjustment
Power supply (*2)
Power consumption
Operation indicator
: GC 365 R / GC 365 SF
: Black
: 2.0 (6'7") to 3.5 m (11'6")
: See
DETECTION AREA
: Active infrared reflection (*1)
Radar doppler effect
: AIR area -6 to +6 °
Radar area +25 to +45 °
: 12 to 24 VAC ±10 % (50 / 60 Hz)
12 to 30 VDC ±10 %
: < 2.5 W (< 4 VA at AC)
: See Operation indicator table
Output hold time
Response time
Operating
temperature
Relative air humidity
: <500 ms
: <300 ms
: -20 to +55 °C (-4 to 131 °F)
: <80 %(non-condensing)
The specifications herein are subject to change without prior notice due to improvements.
NOTE
MANUFACTURER'S STATEMENT
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise
it may cause electric shock or breakdown of the equipment.
Danger of electric shock
WARNING
CAUTION
NOTE
Disregard of the warning symbol can cause improper operation which may cause death
or serious injury.
Special attention is required to the section of this symbol.
Disregard of the caution symbol can cause improper operation which may cause injury of a
person or damage the object.
NOTE
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of
a person.The meanings of the symbols are as follows.
1. This product is a non-contact switch intended for operator cover mount or wall mount for use on an
automatic sliding door. Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to
the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which
the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the building
owner/operator on proper operation of the door and the product.
7.The product settings can only be changed by an installer or service engineer. When changed, the
changed settings and the date shall be registered in the maintenance logbook accompanying the door.
The actual detection area may become smaller depending on the ambient light, the color / material of
the object or the floor as well as the entry speed of the object.
The sensor may not be activated when the entering speed of the object or a person is slower than
50 mm / s or faster than 1500 mm / s
NOTE
[mm (inch)]
Operation indicator table
CAUTION
Risk of getting caught
Make sure to affix the mounting template as described in the above chart,
otherwise it can be dangerous since there may be no detection area around
the threshold. Install the sensor as low as possible on the operator cover.
WARNING
Danger of electric shock
Do not use the sensor without the cover.
When using the cable knockout, install the sensor indoors or use the rain cover
(Separately available) otherwise electric shock or breakdown of
the sensor may occur.
Before starting the procedure, make sure that the power is turned OFF.
When passing the cable through the hole, do not tear the shield
otherwise it may cause electric shock or breakdown of the sensor.
1.Plug the connector.
2.Supply power to the sensor. Adjust the detection area and set the DIP-switches.
(See ADJUSTMENTS 4. DIP-switch settings)
Place the housing cover.
If wiring is to be exposed, break the knockout.
H : Height from the floor to the bottom of the operator cover.
Y : Distance between the bottom of the operator cover and the sensor
X : Distance between the door and the mounting surface
WARNING
Danger of electric shock
NOTE
Make sure to connect the cable correctly to the door controller before turning the power ON.
When turning the power ON or after adjusting the settings, do not enter the detection area for more
than 10 seconds in order to enable the presence detection.
Do not touch the DIP-switches before turning the power ON, otherwise an error occurs.
After changing the DIP-switch and/or potentiometer settings, make sure to push the function switch
INSTALLATION
The following conditions are not suitable for sensor installation.
-Fog or exhaust emission around the door
-Wet floor
-Vibrating operator cover or mounting surface
-Moving objects, steel plate, emergency lights or illumination in the detection area or in vicinity
-Highly reflecting floor or highly reflecting objects around the door
- Make sure that the operator's hood has been earthed.
NOTE
X
H
Y
Sensor
Door
Operator cover
Floor
SPECIFICATIONS
(10)
(1)
(4) (5) (8)(6)
(9)
(3)
Noise level : <70dBA
1. Affix the mounting template at the desired mounting position.
2. Drill two mounting holes of ø3.4 mm (ø1/8”).
3. To pass the cable through the operator cover, drill a wiring hole of ø8 mm (ø5/16”).
4. Remove the mounting template.
5. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.
1
2
3
4
AIR
Mounting height : 2.2 m(7'3")
Vertical adjustment : +35 °
Sensitivity : High
Area width : wide
Speed of detection object
: 50 mm / s
Mounting height : 2.2 m(7'3")
Angle adjustment : +6 °
Sensitivity : Middle
: IR spots
: Detection area
: IR spots
(can be turned off)
: Detection area
AutSchR
1000 ms
Set-up
Installation mode
Operating mode
Adjustment confirmation required
Signal saturation
Sensor failure / sensitivity too low
2nd row detection
Lookback (1st row) detection(*4)
3rd row detection
Radar detection
Status
Yellow Blinking
Green
Red & Green Blinking
Slow Green Blinking
Fast Green Blinking
Yellow
Orange
Red
Operation indicator color
Red Blinking
Blue
(7)
LOOKBACK AREA
When DIP-switch 15 is set to
"
ON
"
, the lookback area, that provides extra safety over the threshold, is activated.
In case the lookback function is not required, set DIP-switch 15 to
"
OFF
"
.
Do not set the 2nd row overlapping the threshold regardless of the setting of DIP-switch 15.
Lookback
(1st row)
2nd row
3rd row
Lookback
(1st row)
2nd row
3rd row
1
2
3
4
GC 365 R
*2 : The sensor has to be connected to a door system which has a SELV circuit.
*4 : See LOOKBACK AREA
*1 : Active infrared reflection has a presence detection function.
*3 : Overcurrent protection with less than 2 A.
Table 1
Cat.
AIR
part
Radar
part
PL
Cat.
PL
GC 365 SF
d (EN ISO13849-1 : 2008)
d (EN ISO13849-1 : 2008)
2 (EN ISO13849-1 : 2008)
3 (EN ISO13849-1 : 2008)
Test conditions required by EN 16005 and DIN 18650
Floor :Grey paper
Detection object : EN 16005 and DIN 18650 CA reference body
Sensitivity : Middle
Speed of detection object : 50 mm / s
To comply with EN 16005 and DIN 18650, make sure that the detection area is within the values of the chart below.
AIR detection area
The chart shows the values at depth angle +6 °
AIR emitting area
A
X
G
I*
2.20 (7'3")2.00 (6'7")
0.25 (10")
1.12 (3'8")
2.65 (8'8")
3.00 (9'10")
0.34 (1'1")
1.53 (5')
3.60 (11'10")
0.23 (9")
1.02 (3'4")
2.41 (7'11")
[m(feet,inch)]
A
C
B
G
H
I
0
1.0
(3′3")
1.0(3′3")
2.0(6′7")
1.0
(3′3")
2.0
(6′7")
2.0
(6′7")
Lookback (1st row)
3rd row
D
E
F
A
B
C
D
E
F
G
H
2.20 (7'3")
0.08 (3")
0.25 (10")
0.39 (1'3")
0.65 (2'2")
1.33 (4'4")
2.70 (8'10")
0.10 (4")
0.31 (1')
3.00 (9'10")
0.11 (4")
0.34 (1'1")
0.48(1'7")
0.80 (2'7")
0.53 (1'9")
0.89 (2'11")
1.63 (5'4") 1.81 (5'11")
2.50 (8'2")
0.09 (4")
0.28 (11")
0.44 (1'5")
0.74 (2'5")
1.51(4'11")
2.00 (6'7")
0.07(3")
0.06 (2") 0.074(3") 0.08 (3")0.07 (3")0.05(2")
0.23 (9")
0.35 (1'2")
0.59 (1'11")
1.21 (3'12")
2.05 (6'9") 2.51 (8'3") 2.79 (9'2")2.32 (7'7")1.86 (6'1")
I 2.78 (9'1") 3.40 (11'2") 3.79 (12'5")
3.50 (11'6")
0.12 (5")
0.39 (1'3")
0.61 (2')
1.03(3'5")
2.11 (6'11")
0.09 (4")
3.25 (10'8")
4.42 (14'6")3.15 (10'4")2.52(8'3")
[m(feet,inch)]
Maximum mounting distance (Y)
X
2.00 (6'7")
2.30 (7'7") 2.50 (8'2")
2.80 (9'2")
0
No limit
0.05 (2") 0.13 (5") 0.13 (5") 0.14 (6")
0.10 (4") 0.11 (4")
0.12 (5") 0.12 (5")
0.12 (5")
0.15 (6") 0.10 (4”)
0.10 (4”) 0.11 (4")
0.11 (4")
0.20 (8")
-
0.09 (4”) 0.10 (4”)
0.10 (4”)
0.25 (10")
0.09 (4”)
0.30 (12") -
-
H
0.13 (5")
-
--
- 0.09 (4")
[m (feet,inch)]
3.00 (9'10") 3.50 (11'6")
0.14
(6")
0.12
(5")
0.11
(4")
0.10
(4")
0.09
(4")
-
0
0
0
0
0
0
NOTE
Make sure not to mount the sensor lower than the bottom of operator cover.
X
Mounting
surface
GC 365 R / GC 365 SF
EN 12978:2003 +A1:2009
EN ISO 13849-1:2008 EN ISO 13849-2:2012
EN 16005:2012
EMC Directive 2004/108/EC
EN 61496-3:2001 clause 4. 3. 5 and 5. 4. 7. 3
COMPLIED STANDARDS
AND EXTRACT FROM EC DECLARATION OF CONFORMITY
Test input
Radar output
Safety output
IP rate
Category
Weight
Accessories
Performance level
ESPE
2nd row
EN 61000-6-2:2005
EN 61000-6-3:2007 +A1:2011
Original instructions
(The mounting height is "H + Y".)
*: When installed at higher than 3.0 m(9'10"), EN 16005 and DIN 18650 requirements are fulfilled only within
the area width "I" of 3.6 m(11'10").
(When setting the detection area close to the door, mount the sensor according to the chart below.)
for 2 seconds.
: Opto coupler
Voltage 5 to 30 VDC
Current 6 mA Max. (30 VDC)
: See INSTALLATION 2
: Opto coupler (NPN)
Voltage 5 to 50 VDC
Current 100 mA Max.
Dark current 600 nA Max.
(Resistance load)
: IP54
: See Table 1
: See Table 1
: 270 g (9.5 oz )
: 1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
1 Cable 3 m (9'10")
( 8×0.22 mm² AWG24 ) (*3)
:
Type 2
GC 365 R
1000 ms
R & TTE Directive
GC 365 SF
Radar
DIN18650-1:2010
The values above are those of the AIR detection area when tested referring to the test conditions of
EN 16005 and DIN 18650. (The emitting area is as shown in AIR emitting area above.)
GND
GND
24V
24V
TST
SIS2
GND
24V
TST
GND
SIS1
24V
SIS1
BN
WH
BU
PK
BK
RD
COM
+
100 mA
1
2
11
1
2
10
1
2
SIS2
12
1
2
10
or
GND
24V
KA
GR
YE
GND
24V
KI
2
23
1
+UB
RBM
KI
2
21
1
1
AIR
2 Test
1
2
KA
12 to 24 VAC±10 % / 12 to 30 VDC±10 %
Opto coupler / Voltage: 5 to 30 VDC
WH
BN
Opto coupler(NPN) / Voltage: 5 to 50 VDC
BU(-)
PK(
+)
BK(
-)
RD(
+)
Form A relay
50 V 0.3 A Max.
Frequency output
100 Hz±10 %
GR
YE
GR
YE
Machinery Directive 2006/42/EC
61(2 3/8")
267(10 1/2")
125(4 15/16")
36(1 7/16") 43(1 11/16")
7.5(5/16")
(2)
COM
1
AIR
2 Test
100 mA
+
1
2
12
1
2
10
or
-UB
+UB
BN
WH
BU
PK
BK
RD
SIS1
GND
24V
SIS1
GND
24V
TST
1
2
11
1
2
10
GND
24V
SIS2
GND
24V
TST
SIS2
24V
KI
GR
YE
RBM
2
23
24V
KA
2
21
KI
KA
1
2
GND
1
GND
1