CommissioningGC 339
5 Commissioning
5.1 Protection area
The position of the IR curtain in relation to the door can be checked using
a spot nder.
X
Activate 4 visible
spots.*
X
Adapt the angle of the AIR
curtain.
Yellow LED is ashing
on spot nder :
Alignment correct.
2x
max. 9 cm
max. 20 cm
* Visibility depends on the environmental conditions.