EasyManua.ls Logo

GEZE TS4000 User Manual

GEZE TS4000
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Components Checklist: Tools Required For Installation:
1 x Closer body and cover 4 x 5 x 55mm Self-tapping countersunk screws Flat head screwdriver 5mm Allen key (supplied)
1 x Arm assembly 4 x M5 x 55mm Countersunk screws Posidrive screwdriver M5 Tap and Tap wrench
1 x Adjustment screw (fitted to arm) Power drill (steel door mounting)
1 x M6 Allen bolt 4.2mm drill bit
4 x M5 x 20mm Pan head screws Template (supplied)
1 x Plastic spindle cover Pencil
10mm Spanner
TS4000/DA Series
Overhead Door Closer
Installation Instructions
WARNING: DOOR CLOSERS WITH A POWER RATING
LOWER THAN 3 OR WITH MECHANICAL HOLD OPEN
DEVICES ARE NOT SUITABLE FOR USE WITH FIRE
DOORS.
IMPORTANT WARNING:
HIGH INTERNAL PRESSURES, UNDER NO CIRCUMSTANCES
A
TTEMPT TO DISMANTLE THE CLOSER.
User Information for Door Closers
This information must be observed. Non compliance will
absolve the manufacture from any liability. The door close
r
must only be used in accordance with its intended use; i.e.
closing of side hung doors following manual opening.
Incorrect use may cause injury
¾ Obstruction of closing process (e.g. dragging doors,
sticking weather strips/sealing rubbers, rough-running
locks)
¾ Incorrect installation and adjustment (e.g. slamming
doors)
¾ Danger of finger trap between frame and door leaf.
¾ Wrong size door closer.
¾ Closer used for other purpose than to close side hung
doors.
Maintenance:
NOTE:
¾ Maintenance to be carried out by a specialist only.
¾ Check assembly for tolerance and undue wear.
¾ Tighten any screws that may have become loose.
At least once a year:
¾ Grease moveable parts.
¾ Check operation of doors and adjust if necessary.
¾ For door closers subject to release by Electro
Mechanical and Electro Hydraulic means ensure that
local regulation are adhered to.
Installation and adjustment by specialist only
Where necessary, an additional doorstop or buffer must be
fitted to limit the maximum opening of the door. This is o
f
particular relevance for slide rail closers where the opening
angle may be limited by frame. For further explanations
see catalogue preface and product information.
Door handing - DIN left / right
Stand facing the door on the hinge / pull side. If the hinge
or pivot is to your right hand side the door is considered to
be DIN right. If the hinge or pivot is to your left-hand side
the door is considered to be DIN left.
Question and Answer IconNeed help?

Do you have a question about the GEZE TS4000 and is the answer not in the manual?

GEZE TS4000 Specifications

General IconGeneral
Door widthup to 1400 mm
Closing speedAdjustable
Latching actionAdjustable
BackcheckAdjustable
TypeOverhead door closer
Opening angleup to 180°
Installation typeSurface mounted
Hold-open functionOptional

Summary

TS4000/DA Series Overhead Door Closer Installation Instructions

Components Checklist

Lists all parts included with the door closer for installation and assembly.

Tools Required For Installation

Outlines the necessary tools for performing the door closer installation.

User Information and Safety Guidelines

Provides critical information on proper usage and potential hazards for door closers.

Maintenance Recommendations

Details periodic checks and upkeep required for the door closer.

Door Handing Identification

Explains how to determine if a door is DIN left or DIN right for correct installation.

Standard Arm Fixing Procedure

Step-by-step guide for installing the TS4000/DA with a standard v-arm.

Parallel Arm Bracket Fixing

Instructions for mounting the TS4000/DA using a parallel arm bracket.