10
Parameters for hinged lip mode
2. Select the program function 3. Time selection
Min lip advance time 0,1 - 3,0 Seconds
Max lip advance time 1,0 - 20,0 Seconds
Max platform raising time 1,0 - 20,0 Seconds
Autoreturn raising time 1,0 - 20,0 Seconds
Autoreturn lowering time 1,0 - 20,0 Seconds
Parameters for extendible lip mode
2. Select the program function 3. Time selection
Min lip advance time 0,1 - 3,0 Seconds
Max lip advance time 1,0 - 20,0 Seconds
Max lip retract time 1,0 - 20,0 Seconds
Min platform raising time 0,1 - 3,0 Seconds
Max platform raising time 1,0 - 20,0 Seconds
Autoreturn raising time 1,0 - 20,0 Seconds
Autoreturn lowering time 1,0 - 20,0 Seconds
Autoreturn reverse 0,0 - 1,5 Seconds
5. Exit programming
Rapid adjustment ends automatically when the last program function is set. The controller
switches to P0.