20
Dock leveller with telescopic lip (2 valves)
Pressing the “Open” button ①
The platform is raised.
Releasing the “Open” button
Platform stops rising and is lowered after
2 seconds, provided that no further command
is issued.
Pressing the “Telescopic lip” button ②
The telescopic lip extends.
Releasing the “Telescopic lip” button
The telescopic lip stops moving and the
platform is slowly lowered.
The process is complete when the telescopic
lip rests on the loading surface.
Movement across the dock leveller is now
possible.
Telescopic lip correction
If the telescopic lip is extended, it is retracted by pressing the “Open” button ①.