EasyManua.ls Logo

GGMgastro CAPRI - Page 6

Default Icon
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5
5. UNPACKING, ASSEMBLY AND PUTTING INTO
OPERATION
5. 1. Inside the premise put the device on wooden pallet and transport it with the fork
lift or lift cart with carrying capacity equal or higher than device's gross weight.
TO AVOID DAMAGING THE REFRIGERATING AND ELECTRICAL SYSTEMS
THE DEVICES HAS TO BE PLACES ON A WOODEN PALLET FOR IT TO BE
MOVED WITH A FORK LIFT!
5. 2. Carefully release the device out of the package, so as not to allow any
mechanical damage to any of its elements.
5. 3. Remove any parts, holding the doors in transportable position. Take all the
documents and additional parts and components from inside the package. Read and
understand the manual for the device. Inspect the contents for any damaged and missing
parts.
5. 4. Remove the device from the wooden pallet, unscrew the fastening bolts, screw
in the supports in their place. Devices with overhead refrigeration device, remove the nails
from the pallet, unscrew the 2 bolts, dismantle the fastening, install the self-driving screws
back and mount the cabinet leg into the support.
Regulate the support to put the device into a stable horizontal position, and angle it
away from the customer to ensure zero-noise performance and correct condensate
accumulation, eliminate the possible skewness and yawns between the doors.
I m p o r t a n t if the device was tilted by more than 15
о
, do not power on the
device for a day's time to avoid the oil from compressor crankcase spilling into suction
intake. This may result in device's failure.
5. 5. When placing the device, leave at least 100mm gap between the wall and
device's back wall. Do not install the device closer than 2 meters from heating units, under
direct sunlight, air drafts, caused by opening doors, windows or artificial climate (creating
air flows stronger than 0.2m/s) or in premises with humidity level violating the limits set
in article 1.3. of this manual! Failure to follow these recommendations may lower the
device's performance or cause a breakdown, not covered by warranty.
5. 6. To install the rack-shelves install the brackets into beam channels on necessary
height (4 brackets per rack-shelf). Install rack-shelves onto the brackets. Install the
handles.
5. 7. Panel and door covering, as well as shields are supplied covered in removable
protective film.
5. 8. Wash the inner and outer surfaces with neutral detergent, and with clean warm
water, then dry it with soft cloth.
5. 9. Check the following conditions before commissioning:
integrity of the refrigerating system;
melt-water (condensate) draining system.
5. 10. If the device was stored or transported in temperatures lower than
12
о
С, connect the device to the power grid after additional storage in the temperature
higher than +12
о
С for 12 hours minimum +12оС, the devices need to be kept in
temperature above +12оС for 12 hours minimum
I m p o r t a n t do not connect a cold device to power grid. This may cause
compressor jam and put the device out of order.