7
1 2
Pic. 2 Control panel
Controller (1) serves to automatically maintain set temperature level in the
refrigerated enclosure and control the evaporator defrosting process. Manufacturers
setting provide the optimal performance of the device. Changing the controller settings
must be conducted by qualified technical personnel of the service provider, and in
accordance with the controller manual.
The switch (2) controls lighting inside the cabinet.
I m p o r t a n t
If your region has frequent power outages, the disruptions in controller
performance may lead to ice build-up on the evaporator. To prevent the wrong
temperature conditions, disconnect the device from the power grid (pulling the cord out
of the outlet socket) to let the evaporator defrost. In case of frequent power outages,
ask the service provider technician to change the settings so that new cycle started with
defrosting.
7. 3. Basic circuit diagram is shown in Appendix B.
7. 4. 4. Before filing the effective volume with products, power up the device, and
wait for the temperature inside the volume to reach the set parameter.
7. 5. Load the device with products, pre-cooled (frozen) to the temperature of the
effective volume. Spread them equally, leaving no empty spaces. Do not overload the
shelves.
Conditions for normal air circulation:
– leave at least a 10mm gap between the products;
– leave at least a 10mm gap between the products and the side walls in the cabinet.
The gap between the products and the back wall cannot be smaller than 25mm;
– the loading height should me 25mm less than the distance between the 2 adjacent
rack-shelf;
– the gap between the products and the air outlets should be at least 50mm;
– do not obstruct the air path and do not put paper, plastic film or any other air-proof
material.
Failure to follow these rules inhibits air circulation, lowers operation characteristics
of the device which might spoil the food items.
DO NOT STORE EXPLOSIVE ITEMS, SUCH AS AEROSOL SPRAYS WITH
INFLAMMABLE LIQUIDS.
AVOID STEPPING ONTO THE DEVICE TO PREVENT ITS DEFORMATION OR
OVERTURNING. THIS MAY ALSO CAUSE INJURIES.
I m p o r t a n t
1. Compressor works in cycles and turns upon reaching set temperature. Upon
the temperature rising by 2-3
о
С, it will turn on again. Different sport in the effective
volume may differ depending on the distance from the air cooler. Controller shown the
average temperature in the effective volume.